V100 SY Blanking plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 SYJ VK Dimensions L (mm) VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A Applicable fittings fitting d Model A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 16 16 18
SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.
A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.
Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21
BT-04 BT-06 BT-08 BT-08 D-A3
Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21
Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21
(Tolerance 30%) Main Circuit of switch OUT(+) Brown (Red) OUT() Blue (Black) 46 Medium Duty Air Cylinder Series NCA1 Specifications PLC: Programmable Logic Controller Grommet D-F59F The output signal can be detected in an unsteady detecting area.
N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40W-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50W-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D Contents Page 1.
Inches Example: 04 = 4 Stroke S T R O K E Hundredths Of An Inch Example: 25 = 0.25 (1/4) Inch Stroke Up to 32 Bore available Please contact P/A Customer Service REFER TO PAGE 22 FOR OPTIONAL ROD THREADS 2 Air Cylinder Expanded Series NCA1 SERIES NCA1 MEDIUM DUTY LARGE BORE PNEUMATIC CYLINDERS B O R E S I Z E S 5 ~ 8 Aluminum Construction Replaceable Rod Gland Design Auto Switch Capable
RHC-F080 RHC-F100 Auto Switch Mounting Bracket Part Numbers (Band and screw included) Bore size (mm) Applicable auto switches 20 25 32 40 50 63 80 100 D-C73, D-C76, D-C80 D-C73C, D-C80C Reed BMA2-020 BMA2-025 BMA2-032 BMA2-040 BMA2-050 BMA2-063 D-H7A1, D-H7A2, D-H7B, D-H7C D-H7NW, D-H7PW, D-H7BW D-H7LF, D-H7NF, D-H7BAL Solid state D-B53, D-B54, D-B64, D-B59W Reed BA-01 BA-02 BA-32 BA-04
For Water 30 20 VX2 60-02 10 VX234.5 VX2 46 VX2 6010 VX2 50 8 3 2 04 03 3 2 3 2 VX223 10 3 2 VX2112 5 4 3 Flow rate Q l/min 2 1 0.001 (0.0018) (0.0054) 0.01 (0.017) 0.05 (0.07) 0.1 Pressure differential P = (P1 P2) MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).
5 to 100C) For low temp. environments (30 to 60C) T Note 4) Semi-standard Type of setting L Note 5), 6) 0 1 Note 1) Basic type (Knob) Air operated type Suffix 2 Set pressure range Nil For IR1000/2000 series Port size Bracket, Name plate, Mounting on the opposite side R Note 7) 0 1 2 0.005 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa Application Size Symbol IR1000 IR2000 IR3000 01 02 03 04
-5 Oil distributor Auto feed tank 1047
ALF400 to 900, ALT-5/-9 Series Operating Pressure Range Tank and line pressure How to Order
Inches Example: 04 = 4 Stroke S T R O K E Hundredths Of An Inch Example: 25 = 0.25 (1/4) Inch Stroke Up to 32 Bore available Please contact SMC Customer Service REFER TO PAGE 22 FOR OPTIONAL ROD THREADS 2 Air Cylinder Expanded Series NCA1 SERIES NCA1 MEDIUM DUTY LARGE BORE PNEUMATIC CYLINDERS B O R E S I Z E S 5 ~ 8 Aluminum Construction Replaceable Rod Gland Design Auto Switch Capable
Grommet (G): VQZ2 2(R)G -N3T, N7T, M5T N3T: One-touch fittings for 5/32" N7T: One-touch fittings for 1/4" 23.5 Mounting holes 70 300 M5T: M5 thread 19.3 (Lead wire length) R2.7 22.5 29.5 A 11 15 SMC 27 34 2 8 Cover diameter 1.4 Cross sectional area 0.2mm2 3.5 20.5 34 Manual override M3 x 0.5 External pilot port 22.7 Mounting holes (Only external pilot port type(R)) 25 10 (N3T, N7T) (M5T)
(Refer to page 46 for details.) -45No.PS-OMW0012-C Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and memorized from the measured pressure.
(mm) d L 6 5 18 10 5 20 16 13 33 d 20 14 40 L 25 14 46 32 16 56 9/10 3. Maintenance ! Caution As a jig is required for bore size 6, do not disassemble when replacing seals etc. If overhaul is required, contact SMC Sales Office.
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 10 8 9.2 6 15.5 5 10 9.2 M5 x 0.8 4 20.5 8 16 8 9.2 8 16.5 6 16 11.5 M6 x 1.0 5 22.5 10 20 8 9.2 10 18.5 6 20 15 M8 x 1.25 5 24.5 13 25 10 11.5 12 22.5 11 25 19.6 M10 x 1.25 6 33.5 17 28 14 16 16 28.5 12 28 25.4 M14 x 1.5 8 40.5 22 Applicable bore (mm) Part no.