SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-09-M3"

Gasket Round head combination screw 7 8 Rc (PT) SY5000-11-14 SY7000-11-13 SY3000-11-25 SY9000-11-2 SY9000-18-2 (M3 x 42) NBR For mounting valves (Flat nickel plated) G (PF) NPTF N NPT M3 x 26 M4 x 31 SY3000-23-4 (M2 x 21) T F 1.2-31 Base Mounted Type How to Order Pilot Valve Assemblies How to Order Connector Assemblies Q 5 G SY114 30 4A SY100 DC: 30 A SY100 Without lead wire: Indicator light

M3 x 0.5 x 3L M8 x 1.25 x 8L (Bolt holder) (Hexagon socket head set screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 16 32 2-M3 x 0.5 through 6.5 counter bore depth 5 (Same on the opposite side) 3.4 through 3 3 45 45 5.5 M2.5 x 0.45 x 6L (Cap screw) M3 x 0.5 x 12.5L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2-M3 x 0.5 through Steel ball Plug 2-M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no

782 MXS 1322Air Slide Table Dimensions: MXS8 1322Basic 2 x M3 x 0.5 thread depth 4 Operating port 2 x M5 x 0.8 7 2 Vacuum suction port M5 x 0.8 5.5 J 6 Max. 9.5 (Stroke adjuster at retraction end) I 8 6.5 4 6.5 7 7 3.5 3.8 NA x M3 x 0.5 thread depth 4 14.6 K 7 3.8 KA 14.6 22 (With stroke adjuster at extension end) Stroke adjuster at extension end Stroke adjuster at retraction end N x M3 x

(ANR) oil mist concentration (before saturated with hydraulic fluid: 0.01mg/m3 (ANR) or less, approx. 0.008ppm ) Note 1) Pressure gauge connection threads are not required for the regulator with a square embedded type pressure gauge (AWD20 to 40).

0 M3 x 28l Stainless steel Hex. socket head cap screw with spring washer Exhaust throttle with silencer ASN2-M5 !1 @8 M3 x 10l Port size: 6 Stainless steel Hex. socket head cap screw with spring washer One-touch fitting @9 !2 Aluminum alloy Plate Metallic painted !3 Replacement Parts Aluminum alloy Sub-plate Metallic painted !4 Refer to the How to order below.

0 M3 x 28l Stainless steel Hex. socket head cap screw with spring washer Exhaust throttle with silencer ASN2-M5 @8 !1 M3 x 10l Port size: 6 Stainless steel Hex. socket head cap screw with spring washer One-touch fitting @9 !2 Aluminum alloy Plate Metallic painted !3 Replacement Parts Aluminum alloy Sub-plate Metallic painted !4 Refer to the How to order below.

31 31 16 13 13 13 125 46.5 37.5 33.5 28 7 5.5 5.5 5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 15 11.5 10.5 8.5 40 32 25 20 66 60 60 60 75 75 75 24 22 22 18 22 17 17 13 41 32 32 26 31 26 26 26 50 45 45 41 174 140 138 134 M26 x 1.5 M26 x 1.5 M20 x 1.5 21 19.5 19.5 15.5 17.5 17.5 35.5 35.5 26-0.033 0 14 12 10 16 13 13 7 7 7 5 4 4 1/4 1/8 1/8 163 131 129 26-0.033 0 17.5 35.5 32-0.039 0 10 8

( 0.8 ppm) [AFD] Max. 0.1 mg/m3 (Before saturated with oil 0.01 mg/m3 or less 0.008 ppm) Compressed air purity class*5 [AFM] ISO 8573-1:2010 [ 3 : 7 : 3 ]*6 [AFD] ISO 8573-1:2010 [ 1 : 7 : 2 ]*7 Drain capacity 8 cm3 25 cm3 45 cm3 Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight 0.10 kg 0.18 kg 0.37 kg 0.40 kg *1 Inlet pressure: 0.7 MPa.

SY3000 SY3000-23-4 (M2 x 21) M3 x 26 (Flat nickel plated) M4 x 31 (Flat nickel plated) SY3000-11-24 SY5000 SY5000-11-10 SY7000 SY7000-11-9 Note 2) For SY9000, the SUP port is only available on the end plate side. SY9000-18-2 (M3 x 42) SY9000 SY9000-11-1 Plug (white) Insert into unused cylinder ports and SUP/EXH ports. The minimum order quantity is 10 pieces. Order in multiples of 10.

(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.

(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.

X-axis Y-axis Z-axis X Z W 10 mm 10 mm 40 mm 2 kg 10 Y Y 3 Calculation of Load Factor for Static Load m3: Weight m3 max (from q of graph MY3M m3) = 5.33 (kg) m3 Load factor 1 = m3 / m3 max = 2 5.33 = 0.38 Z M2: Moment M2 max (from w of graph MY3M M2) = 6 (Nm) M2 = m3 x g x Z = 2 x 9.8 x 40 x 10-3 = 0.78 (Nm) m3 Load factor 2 = M2 M2 max = 0.78 6 = 0.13 M2 M3: Moment X M3 max (from e

VK 31 Type How to Order Applicable solenoid valve (1) VZ SS3Y1 31 05 SY113-l-M3 SY113A-l-M3 SY123-l-M3 SY123A-l-M3 VT Stations 02 VT 2 stations ... ... Applicable blank plate assembly SY100-77-1A P R 20 stations VP 20 R port M5 X 0.8 P port M5 X 0.8 VG VP Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold.

Bit offset Item Notes 0 OUT1 output 0: OFF 1: ON 1 OUT2 output 0: OFF 1: ON 8 Measurement diagnostics 0: Within range 1: Out of range (HHH) 14 Fixed output 0: Normal output 1: Fixed output (Setting of output check) 15 Error Diagnosis 0: Error not generated 1: Error generated 16 to 31 Flow measurement value With sign: 16 bit Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item Flow

PLC H.T. ) Enable 1 (SC_MonOp) 1 Disable Auto (SC_RstOp) 2 Manual Enable 3 (OC_Mon) Disable Clear OFF 2 Hold 4 (Fault_MD) ForceON ON Clear OFF Hold 5 2 (Idle_MD) ForceON ON Enable Val165000 4 ON 3 ON/OFF (Counter) 6 Disable 1: () 2Hold/Clear Handheld 31 4x1000 -55No.EX-OMN0027CN-D No. (H.T.

20.4 10 14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31

1 Hexagon socket head screw Steel M3 x 32 M3 x 32 M3 x 32 !2 Detent assembly VFS3000-9A Refer to How to Order Pilot Valve Assembly on page 3-8-54. Pilot valve assembly !

CRBU2 CRB1 L1 + (3 x P) L1 + (3 x P) Q1 = M Q1 = M MSU L2 + (3 x P) L2 + (3 x P) L1 = L1 = CRJ L2 = L2 = Q2 = M Q2 = M CRA1 Size 10, 15 Size 20, 30, 40 Size 10, 15 Size 20, 30, 40 CRQ2 (mm) (mm) Q1 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 Q2 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 Size 10 15 20 30 40 Size 10 15 20 30 40 MSQ MSZ CRQ2X MSQX Symbol: A4 Symbol: A5 Symbol: A3 The long shaft can be

M3 screw For details on specifications and handling, refer to the separate technical instruction manual.

Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the known unit. Also, the flow characteristics line shown in the Graph (2).