Up to 400 35 32 75 27 58 18 38 6 11 51 11 M8 x 1.25 7 16 11 M18 x 1.5 22 1/4 73 135 80 Up to 500 40 37 88 32 69 22 45 12 13 62 13 M8 x 1.25 7 19 13 M22 x 1.5 26 1/4 83 158 85 Up to 500 40 37 95 32 74 22 45 12 13 62 13 M10 x 1.25 7 19 14 M22 x 1.5 26 1/4 83 159 100 Up to 500 40 37 110 41 87 26 50 10 14 66 16 M10 x 1.25 12 23 14 M26 x 1.5 28 3/8 88 168 Rod end nut (Standard) 30 d D C H B [mm
175, 200 50.5 75.5 50.5 52.5 39 41 10 10 0 25 23 9 2.5 25 50.5 77 50.5 53.5 37.5 40.5 10 14 0 26.5 23.5 10 3 Bore size [mm] G GA GB GC H HA J K L MM ML NN OA OB OL P PA PB PW Q 100 st or less Over 100 st Nil TN TF 12 25 10 6 7 10 54 M5 12.5 12.5 17 M4 x 0.7 10 M4 x 0.7 4.3 8 4.5 M5 x 0.8 11.5 8 16 14 16 29 12.5 5.5 7.5 11.5 59 M3.5 14.5 14.5 20 M5 x 0.8 11 M5 x 0.8 4.3 8 4.5 M5 x 0.8 11.5
AT11C-06 AFF8B-04 IDF8DAM350-04 AMD350-04 11 1.5 HAA15-10 HAW22-14 AT11C-06 AFF8B-06 IDF11CAM350-06 AMD450-06 15 2.0 HAA22-14 HAW22-14 AT22C-14 AFF11B-06 IDF15CAM450-06 AMD450-06 22 3.0 HAA37-14 HAW37-14 AT22C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 27 3.5 HAA37-14 HAW37-14 AT37C-14 AFF22B-10 IDF22C1-3 AM550-10 AMD550-10 37 5.0 HAW55-20 AT37C-14 AFF37B-14 IDF37C1-3 AM650-14 AMD650-14
Display for Wireless Base 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for Wireless Remote 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4. Detailed information of units 41 3.4.1. Information tab 41 3.4.2. Details of I/O monitor tab 50 4. Setting Function 57 4.1. Edit TAG 57 4.2.
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 11-11-10 Reed switch Solid state switch CRA1 11-11-11 D-90/97 D-A90/A93/A96 D-A90V/A93V/A96V 11-11-12 CRQ2 Grommet D-90A/93A 11-11-13 Direct MSQ D-R731/R732 11-11-14 D-R801/R802 11-11-14 MRQ 11-11-15 D-R731C/R732C Connector 11-11-15 D-R801C/R802C DRail
35 26 18 13.6 2.7 14 PF3W720 3/8 1/2 78 54 30 60 40.6 15.2 27 18 39 30 18 13.6 2.7 12 PF3W740 1/2 3/4 98 71 38 68 48.6 19.2 32 28 49 35 28 16.8 2.7 12 PF3W711 3/41 124 92 46 77 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W704 24 22 32 40 50 4.5 5 1.5 PF3W720 28 22 32 40 50 4.5 5 1.5 PF3W740 34 30 42 48 58 4.5 5 1.5 PF3W711 44 36 48 58 70 5.5 7 2 -81No.PF-OMM0004-D PF3W721 A AA B
M2 3.0 5.2 9.0 15 24 38 60 3.0 5.0 8.5 14 23 35 50 M3 1.0 1.7 2.4 5.0 8.0 15 19 2.0 3.0 5.0 10 20 35 50 m2 7 10.4 15 23 33 48 72 7 10 14 21 30 42 60 m3 2.1 3 4.5 6.6 10 14 21 2.1 3 4.2 6 8.2 11.5 16 16 20 25 32 40 50 63 16 20 25 32 40 50 63 MY1MW MX MTS MY MY1CW CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
M2 3.0 5.2 9.0 15 24 38 60 3.0 5.0 8.5 14 23 35 50 M3 1.0 1.7 2.4 5.0 8.0 15 19 2.0 3.0 5.0 10 20 35 50 m2 7 10.4 15 23 33 48 72 7 10 14 21 30 42 60 m3 2.1 3 4.5 6.6 10 14 21 2.1 3 4.2 6 8.2 11.5 16 16 20 25 32 40 50 63 16 20 25 32 40 50 63 MY1MW MX MTS MY MY1CW CY MG The above values are the maximum allowable values for moment and load.
Controller Set Up (P.34) and 14. Card Motor Controller Configuration software (P. 57) for instructions on how to setup. (6) Test operation Refer to section 10. Monitor and Test Mode of the Controller (P.41) and 14.5 Monitor/Test window (P. 68) for instructions on operating instruction of test operation 14 - 3.
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
Inch Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FS-01-01 (S) 1/8" 7.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 13 (13) AS221FS-01-03 (S) 5/32" 8.2 AS221FS-01-07 (S) 1/4" 11.2 20.8 27.9 14 (13) AS221FS-01-09 (S) 5/16" 13.2 22.4 29.5 14.2 15 (14) AS221FS-02-01 (S) 1/8" 1/8 13 (12.7) 7.2 20.9
Inch Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FSG-01-01 (S) 1/8" 7.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 13 (13) AS221FSG-01-03 (S) 5/32" 8.2 AS221FSG-01-07 (S) 1/4" 11.2 20.8 27.9 14 (13) AS221FSG-01-09 (S) 5/16" 13.2 22.4 29.5 14.2 15 (14) AS221FSG-02-01 (S) 1/8" 1/8 13 (12.7) 7.2
0lT:With 'aNPTF O2TrWith 14 NPTF subplate subplate /R1,R2 Ports \ -^ --
Parameter Configuration using Setup software (MR Configurator2TM) . 14 6.1 Setup software (MR Configurator2TM) .14 6.1.1 Installation Method . 14 6.2 Basic driver set-up for Initial Test Drive .14 6.2.1 Start up the Setup software (MR Configurator2TM) . 15 6.2.2 System Settings . 16 6.2.3 Model Selection . 16 6.2.4 Driver ON LINE Check . 17 6.2.5 Help Function . 17 6.3 Parameter setting (
A B C D E F G H J K Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41 Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50 Ordering Example Dual residual pressure release valve with soft start-up function VP544-5DZ1-03-X538 1 pc. Filter regulator AW30-03G-A 1 pc. Spacer with bracket Spacer with bracket Y300T-A 3 pcs. Piping adapter E300-03-A 2 pcs. Each product is not assembled.
4.2 17 19.95 99.5 54 39 14 4.2 17 19.95 116.5 58.5 41 17 4.2 19 ZH15DS-02-03-03 22.45 116.5 58.5 41 17 4.2 19 ZH15DL-02-03-03 22.45 (Mounting hole) Model I J K L M N O P Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Rc 3 8 ZH05DS-01-01-01 ZH05DL-01-01-01 ZH07DS-01-01-01 ZH07DL-01-01-01 ZH10DS-01-01-01 ZH10DL-01-01-01 ZH13DS-01-02-02 ZH13DL
o 0lT:With 'aNPTF O2TrWith 14 NPTF subplate subplate /R1,R2 Ports \ -^ --
M5 x 18 Tightening torque 4.4Nm0.2Nm M3 x 14 Pulley cover mounting process Pulley cover TP-M3 x 5 TP-M3 x 5 Pulley cover mounting process 1. Mount the pulley cover using thin head screws. Confirm there is no rattle on the pulley cover. 19 Electric Actuator/Maintenance Guide 4 Be sure to read before handling.