HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
Make sure not to plug the exhaust port R. 1 8 VK3140 Base mounted 1 8 130 (with sub-plate) VK3140Y (For low wattage 2 W DC) 0.50 0.12 0.11 0.48 0.19 0.12 Plug position B port N. C. A port N. O.
(Values at the initial period) Solenoid Specifications Electrical entry Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.
Item Specifications Conductor Nominal cross section AWG26 Outside diameter Approx. 1.00 mm Insulator Colours Brown, White, Black, Blue +0.10 Sheath Outside diameter 3.5 -0.25 -67No.PF-OMO0005-F Characteristics data Analogue output A B C Voltage output 1 V 1.04 V 5 V Current output 4 mA 4.16 mA 20 mA Model Minimum flow of rated flow range Maximum flow of rated flow range PFMB7201 2 L/min 200
1.3 to 10.6 0.9 to 14.5 125 to 1000 0 to 1372 100 L 2.6 to 26.4 1.9 to 37.0 100 to 1000 0 to 1400 250 L 13 to 66 5 to 92 200 to 1000 0 to 1400 Temperature value PD value Series Unit Flow Rated temperature Display/settable Rated temperature Display/settable range range range range range Min. to Max.
1.33 to 1060 0.92 to 14.50 125 to 1000 0 to 1372 100 L 2.6 to 26.4 1.9 to 37.0 100 to 1000 0 to 1400 250 L 13 to 66 5 to 92 200 to 1000 0 to 1400 Temperature value PD value Series Unit Flow Rated temperature Display/settable Rated temperature Display/settable range range range range range Min. to Max.
Dimensions E C D E E L (Width across flats) M (Width across flats) M8 (KF Flange) (K Flange) Fn Fd C Detail of (a) (a) M Rc1/8 J H K B A G A Model A B C D E Fn Fd XLGR-80*-1* 90 250 117 45.5 38.5 114 110 XLGR-100*-1* 108 270.5 154 55 38.5 130 102 XLGR-160*-1* 138 339 200 65 38.5 180 153 Model G H J K L M XLGR-80*-1* 83 105 44 9 13 4 XLGR-100*-1* 102 92 58 9 13 4 XLGR-160*-1* 153 124 62 12.5
XMD-40 XYD-40 XMD-50 XYD-50 XMD-63 XYD-63 XMD-80 XYD-80 Flange (valve) size 25 40,CF070 50 63,CF114 80 Actuating type Normally closed(Pressurize to open, spring seal)[both main & initial exhaust valves] Fluid Inactive gas under vacuum Operating temperature oC 5 to 60 (High temperature type: 5 to 150) Operating pressure Pa (abs) Atmospheric pressure to 1 x 10-6 Main pumping 14 45 80 160 200
/ mm mm mm c.p.m. mm(L1-L2) (L1) (L2) g MHL2-10D 60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D
Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
Outer dimensions and descriptions of each part 4Outer dimensions and descriptions of each part 1) Outer dimensions Model HAA15-10 HAA22-14 PORT SIZE 1B union 11/2B union A 460 588 B 394 484 C 33 52 D 70 70 E 59 60 F 485 580 G 428 505 H 320 333 J 150 150 K 150 150 L 320 400 M 70 94 N 58 65 P 200 200 Q 480 610 R 220 220 S 225 238 HAA Series 6 4 1) Outer dimensions ATX-OM-F004E Air-Cooled Aftercooler
. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31
XMA-16 XMA-25 XMA-40 XMA-50 XMA-63 XMA-80 XYA-25 XYA-40 XYA-50 XYA-63 XYA-80 Flange (valve) size 16,CF034 25 40,CF070 50 63,CF114 80 Actuating type Normally closed (Pressurize to open , spring seal) Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (High temperature type:5 to 150) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 160 200
JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
Metric size Inch size 100 200 205 M5 standard 1/8 standard 1/4 standard 3.2 4 6 8 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" Use 1/8" tube.
Model AMD450 AMD550 AMD650 AMD850 AMD150 AMD250 AMD350 Rated flow (l/min (ANR))(1) 2000 3500 6000 12000 200 500 1000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 31/2, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Standing Style/Model Model AMD1000 Rated flow (l/min(ANR)) 8000 AMD800 24000 AMD900 40 Port size (Nominal size B) 2B Flange 2B
AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Rated flow (l/min (ANR))(1) 200 500 1000 2000 3500 6000 12000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 1, 11/2 11/2, 2 3/4, 1 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa.