45 D 32 40 50 E 64 77 98 L 45 54 56 N 9 11 13 O QB 7 8.5 10 B 93 99 128 QA 10 12.5 12.5 GB 16 24 35 Stroke 30 30 40 Bore size (mm) 50 63 80 14 depth 5 18 depth 6 20 depth 6 P (Piping port) TN NPT 1/8 NPT 1/4 NPT 1/4 R 40 47 54 S 21 24.5 31 T 2 3.5 3 U 5.5 6.4 6.7 V 15.5 16 19.4 W 72 87.5 109 WB 32 38.5 49 X 5 5 6 Y 10 10 12.5 Stroke 30 30 40 Bore size (mm) 50 63 80 Model 24 24 23 Nil Rc
(100) 71 (71) 44.5 46 16 Reference dimensions after R(PT) thread installation.
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
45 D 32 40 50 L 45 54 56 N 9 11 13 O QA 10 12.5 12.5 QB 7 8.5 10 GB 16 24 35 Stroke 30 30 40 Bore size (mm) 50 63 80 14 depth 5 18 depth 6 20 depth 6 P (Piping port) TN NPT 1/8 NPT 1/4 NPT 1/4 R 40 47 54 S 21 24.5 31 T 2 3.5 3 U 5.5 6.4 6.7 V 15.5 16 19.4 WB 32 38.5 49 X 5 5 6 Y 10 10 12.5 W 72 87.5 109 Stroke 30 30 40 Bore size (mm) 50 63 80 Model 24 24 23 Nil Rc 1/8 Rc 1/4 Rc 1/4 TF G
T) W Model LVC20 LVC30 LVC40 LVC50 LVC60 (mm) Dimensions 64 S T Model LVC3 LVC4 LVC5 90 24 49.5 110.5 29 54.5 147 34.5 60.5 156 Suck back (Single type) Suck back (Unit type) 50 3.5 4.5 37 30 44 37 30 44 4-3.5 20 (Max. 11.5) 51 51 (Max. 11.5) M5 x 0.8 M5 x 0.8 M5 x 0.8 45 12.5 45 30 SMC SMC SMC A B A B 12.5 61 4 4 30 (110) (78) 17-5-12 10 Series LVC Manifolds Manifold Specifications LLC5A
Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150
Rubber seal Exhaust center 10-SQ1431 39 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less 100 Rubber seal Pressure center 10-SQ1531 39 or less 0.14 0.20 0.59 0.19 0.21 0.79 25 or less 100 Rubber seal Note 1) Values for the cylinder port size of C6, CYL Values of EXH.
75 HA 19.5 39 HB 8.5 19 HG 8.5 19 HI 23 39 HL 38.6 64.9 HP 44 73.5 HS 27 49.5 HT 19.5 39 J M6 x 1 M10 x 1.5 JK 10 12 K 21 20 Model +0.030 0 +0.030 0 CYP15 CYP32 LD 5.6 8.6 LW 69 115 MM M4 x 0.7 M6 x 1 M 6 8 P M5 x 0.8 Rc 1/8 N 4.5 7.5 PA 25 50 PB 60 100 Q 105 138 QW 48 87 R 45 79.5 T 23 29 TA 13 17 TB 18 22 W 69 115 WA 32 46 WB 17 27 Y 2.5 3.5 Z 118 155 L 67 90 Model CYP15 CYP32 Note 1)
75 G 6.5 8.5 F 12.5 25 EK 4 6 ED 9.5 13 E 4H9 6H9 B 9.5 14 A 8 12 C 5.4 8.6 Model +0.030 0 +0.030 0 CYP15 CYP32 L 67 90 Z 118 155 Y 2.5 3.5 WB 17 27 WA 32 46 W 69 115 TB 18 22 TA 13 17 T 23 29 R 45 79.5 QW 48 87 N 4.5 7.5 Q 105 138 M 6 8 PB 60 100 MM M4 x 0.7 M6 x 1 PA 25 50 LW 69 115 P M5 x 0.8 Rc 1/8 LD 5.6 8.6 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping
75 G 6.5 8.5 F 12.5 25 EK 4 6 ED 9.5 13 E 4H9 6H9 B 9.5 14 A 8 12 C 5.4 8.6 Model +0.030 0 +0.030 0 CYP15 CYP32 L 67 90 Z 118 155 Y 2.5 3.5 WB 17 27 WA 32 46 W 69 115 TB 18 22 TA 13 17 T 23 29 R 45 79.5 QW 48 87 N 4.5 7.5 Q 105 138 M 6 8 PB 60 100 MM M4 x 0.7 M6 x 1 PA 25 50 LW 69 115 P M5 x 0.8 Rc 1/8 LD 5.6 8.6 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping
The load voltage is 100 or 200VAC. Use a contact protection box in any of the above situations. The life of the contacts may otherwise be reduced. (They may stay ON all the time.)
m 3/h) (120 m 3/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz 41-122 F (5-50C) 22psig (0.15MPa) 150psig (1.0MPa)
Thread type Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Voltage Port size 1/8 (6A) Class 3 Class 2 Class 4 Symbol 01 02 03 04 06 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Please consult with SMC regarding other voltages.
45 45 45 0.18 Weight (kg) 0.06 0.22 0.49 0.99 1.05 0.45 Accessory part no.
45 Symbol Polycarbonate Option Standard Relieving type 0.40 0.32 0.72 0.75 Note 1) Set the inlet pressure 0.05MPa or higher than the set pressure.
100 100 200 193 193 238 289 289 289 357 293 293 326 354 354 354 428 159 159 215 219 219 219 159 159 245 264 264 264 203 203 266 324 324 324 473 130 130 165 216 216 216 267.3 35 35 138 170 276 276 365 270 480 704 1056 1203 1703 1210 35 35 37 80 150 150 72 395 83 83 212 258 366 366 500 190 390 575 893 1038 1538 950 1 2 1 1 2 1 1 1 1 2 2 3 1 1 1 4 14-15-8
RSH80 RSH80 RSH80 200 200 RSH63 RSH63 RSH63 RSH50 RSH50 RSH50 0.9 Operating pressure : P (MPa) 100 100 0.8 0.7 0 0 10 20 30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40
N.C. 0.003 View port G1/2 0.001 30 50 100 300 500 Flow rate (L/min) Conditions Fluid: Turbine oil Class 2 VG56 Measured pressure: 1 MPa Viscosity: 45 mm2/s Filter material: Micromesh Nominal filtration: 74 m Refer to page 529 for Microswitch for differential pressure indication switch. 519 FH100 Series Dimensions Differential pressure indication switch 62 F Differential pressure indicator
MH*-OMM0056 MHS2-D MHS3-D MHS4-D MHSJ3-D MHSH(J)3-D 1. 23 2. 2-1. 45 3. 3-1. 6 3-2. 67 3-3. 713 3-4. 13 3-5. 14 3-6. 14 3-7. 14 4. 4-1. 14 4-2. 1518 4-3. 1922 4-4. 2326 1 [ ][][] ISO4414*1)JISB8370*2) 1) ISO4414Pneumatic fluid power-Recommendations for the application of equipment to transmission and control systems. 2) JIS B8370 2 1. 2. 3. 4. 3 2 2-1 MHS2 MHS2 -16D MHS2 -20D MHS2 -25D
(50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or equivalent (130C) (6) 51 45 17 (5.3) 11 (2.9) 5.5 50 Hz 60 Hz 50 Hz 60 Hz Inrush Apparent power (VA) (Power consumption (W)) VP AC Holding S070 Power consumption (W) DC Bracket (AXT338-11)/For body ported type VQ Accessory (Option) Indicator