SMC Corporation of America
Elite Part Number Search
Search Results "RZQB63-50-5"

External Grip Internal Grip MHK2-12D MHK2-12D 25 20 Pressure 0.6 MPa Pressure 0.6 MPa Gripping force (N) Gripping force (N) 20 15 0.5 MPa 0.5 MPa 15 0.4 MPa 10 0.4 MPa 10 0.3 MPa F F 0.3 MPa 5 5 0.2 MPa 0.2 MPa 0 0 10 20 30 40 50 10 20 30 40 50 Gripping point L (mm) Gripping point L (mm) External grip Series MHK2 Internal grip Series MHK2 MHK2-16D MHK2-16D 50 50 Pressure 0.6 MPa Pressure

Body class 2 3 4 5 2 to 5 2 to 5 LVC 6 1/4" 6 1/4" LVA 2 2 8 8 10 3/8" 10 3/8" Base type LVH A Stacking type 10 3/8" 10 3/8" Manifold stations LVD 3 3 12 1/2" 12 1/2" 02 2 stations LVQ 12 1/2" 12 1/2" 05 5 stations 4 4 LQ 19, 3/4" 19, 3/4" 12 1/2" 12 1/2" LVN 5 5 19, 3/4" 19, 3/4" TI/ TIL How to Order Valve PA LVC 2 0 S07 A PAX Option PB Body class Nil 1 4 None With flow rate adjustment

Flange material: Carbon steel Rod end nut L1 Double clevis type mm Double clevis/RQD, DQD Bore size (mm) Stroke range (mm) A CL Cap bolt 15 to 50 20 54.5 63.5 CD hole H10 Shaft d9 15 to 50 25 61.5 71.5 mm Bore size (mm) B L L1 CD CU CW CX CZ RR L CU CX CZ CW RR B + Stroke 5 +0.4 +0.2 0.1 0.3 20 4.5 18.5 12 18 16 9 32 8 8 CL + Stroke A + Stroke 25 5 22.5 14 20 20 10 36.5 10 10 (All dimensions

Current read value For example, when the display value is 1.000 [MPa], 5%R.D. is 5% of 1.000 [MPa], which becomes 0.05 [MPa]. When the display value is 0.800 [MPa], 5%R.D. is 5% of 0.800 [MPa], which becomes 0.04 [MPa].

for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins

for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins

valve 02: Rc With sub-plate 1 4 3 position closed center 3 1 4 Note) 5(R1), 3(R2) port: Rc 3(R) port PE port 3 position exhaust center Manual override/Plug-in type Nil: Non-locking push type B: Locking type B (Slotted) C: Locking type C (Manual) Rated voltage 4 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 3 position pressure center 4 0 1 0 1 5 24 VDC 12

Model N E F LXFHSB _ 25 1 5 1 160 138 60 30 (50) LXFHSB _ 50 176 145 90 60 (50) LXFHSB _. 75 6 201 210 188 90 60 100 LXFHsB _ 100 6 226 235 213 90 60 100 tlsclriD lclltolo 0inffsifls .

5 0.2 MPa 0.2 MPa 0 10 20 30 40 50 0 10 20 30 40 50 F1 Gripping point L (mm) Gripping point L (mm) F1 F1 506 Series MHR3/MDHR3 Rotary Actuated Air Gripper 3-Finger Type Construction !

5 No. q w e r t y u i o !0 !11 !2 !33 !4 !5 !

Digital 0.2 to 10 L/min 0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 1 to 10 L/min 50 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 0 to 0.5 L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 1 to 1 L/min 3 to 3 L/min 5 to 500 L/min 2 to 200 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 1000 L/min 10 to 100 L/min 300 to 6000 L/min 20 to 2000 L/min 20 to 200 L/min 600 to 12000

ExIP8001-010-EW F With feedback lever unit for stroke 50 to 140mm. 2: When 52ATEX type specify symbol M, 2, 5, blue cable grant is equipped for electric connection. W With body cover window.

30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 658 180 Angular Style Air Gripper Series MHY2/MHW2 MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 200 0.5 0.5 0.5 60 15 0.4 0.3 0.4 150 0.4 40 0.3 10 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40 Gripping

Depth 7.5 4 x M4 x 0.7 Depth 6 23 5 13 8 18 21.5 46 47 20 20 23 5 6.5 6.5 5 NS 12.5 13 11 7.5 35 + Stroke 46.5 + Stroke 11.5 20 4 x M4 x 0.7 Depth 6 5 + Stroke 12 LT NS LB J LA Stroke (mm) 5 14 49 4 10 10 14 10 49 4 15 59 24 20 4 20 59 24 4 20 25 30 69 4 30 30 30 30 69 4 40 20 79 45 20 6 50 89 55 25 6 25 60 60 99 6 30 30 26 Compact Slide Series MXH Dimensions: 16 LT MXH 24 16 MXU LA

denotes the bottom ported type. 3-6-12 13 Explosion Proof Solenoid Valve Series 50-VFE/50-VPE Specifications: 50-VFE3000/5000 Explosion proof solenoid valve 5 port/50-VFE3000, 5000 3 port/50-VPE500, 700 VK 50-VFE3000 50-VFE5000 Series VZ Fluid Air Quality of explosion proof spec.

tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 Detection

Description RLQ40 RLQ50 RLQ63 Compact Cylinder with Air Cushion and Lock PT elbow Restrictor PT tee 32, 40: AS2200-(N, F)01-S 50, 63: AS2200-(N, F)02-S 32, 40: KRL06-01SW2 50, 63: KRL06-02SW2 TRB0604W KR-06C Metal speed controller 5 2 Dimensions not shown are the same as standard type.

n) t 5 20 25 30 40 50 65 80 100 125 Elbow 0.3 0.4 0.5 0.7 0.8 l . l 1.4 1.8 2.4 3.2 90' Bend (lono) 0.1 0.2 0.3 0.4 0.5 0.6 0.8 0.9 1.2 1.5 90' Elbow 1.0 1.2 1.6 1.8 ?.

Application Example qBlow off valve (SYJ llR) 3 5 7 wValve for vacuum control eOperation of a single acting cylinder rDivider valve (SYJ llR) tSelector valve (SYJ llR) yPressure release Valve (SYJ llR) 3 5 7 3 5 7 3 5 7 (SYJ llR) 3 5 7 3 5 7 3 5 7 (SYJ ll/SYJ ll R) X port X port X port X port X port Tank Tank 0.2MPa (R)3 2(A) (R)3 2(A) 2(A) (R)3 2(A) 2(A) 2(A) (R)3 (P)1 (R)3 (R)3 (P)1 Plug

pin type) Note 3) DO: DIN terminal without connector Note 1) V116 i Rated voltage 1 2 3 4 5 6 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC [115 VAC] 50/60 Hz 220 VAC [230 VAC] 50/60 Hz 24 VDC 12 VDC Note 1) Refer to the below table (1) for combinations with light/surge voltage suppressors.