Size Rod end thread 20 25 32 40 Piston area equivalent to 20 mm Piston area equivalent to 25 mm Piston area equivalent to 32 mm Piston area equivalent to 40 mm Rod end female thread Rod end male thread Nil M Cylinder stroke (mm) Size Stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 20, 25 32, 40 Applicable Auto Switches/Refer to pages 13 through
MA B Auto switch mounting heights D-A9V D-F9V D-F9WV (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL MA MA MA 20 25 25 27 25 27 27.5 29.5 A Approx.
. 9-1 9.1.2 HRLE090-A-20. 9-2 9.1.3 HRLE050-W-20. 9-3 9.1.4 HRLE090-W-20. 9-4 9.1.5 HRLE090-A-40. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40.
10V] +15V 100 + ANALOG CIRCUIT 10 10 Output DI PV Analog Output*3 DI PV Analog Output*3 -15V 22 22 Output ANALOG COM [0 to 20 M:0 to 10V] [0 to 20 M:0 to 10V] +15V 12 Intput Temp.SP Analog Input*3 Temp.SP Analog Input*3 12 + -15V 1M 24 Intput [-100 to 100 deg C:-10 to 10V] [-100 to 100 deg C:-10 to 10V] 24 ANALOG COM 13 Output EMO signal EMO signal 13 25 Output EMO CIRCUIT 25 *1: The recovery
63.5 64.5 34 34 32 7 32 7 6 20 20 11 6 15 NS 15.5 52.5 + Stroke 68 + Stroke 32 4-M5 x 0.8 depth 8 10 + Stroke 15 20 Stroke (mm) LT NS LB J LA 5 20 64 4 10 10 20 10 64 4 15 74 25 20 4 20 74 25 4 20 25 40 84 4 30 30 40 30 84 4 40 20 94 50 20 6 50 104 70 25 6 25 60 70 114 6 30 30 36 Compact Slide MXH Series Auto Switch Specifications Auto Switches/Proper Mounting Position for Stroke
For example, changing from F Kit (D-sub connector) to S Kit (serial transmission) is achieved by simply changing the kit piece. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring (Refer to the connector wiring diagram) Printed circuit board patterns between connectors are shifted at every station
Connection thread size (R, NPT) Tightening torque [Nm] 1/16, 1/8 3 to 5 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 2) If the fitting is tightened with excessive torque, a large amount of sealant will seep out.
Fig. 9-11 Cooling Capacity (HRL100-A-40-T2 CH1) 9.4.6 HRL200-A-40-T2 CH2 30 Ambienttemperature 25 Cooling capacity [kW] 32oC 20 15 45oC 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] This is the cooling capacity of the CH1 side when 1 Kw heat load is applied to the CH2 side.
Rc 1/8 20 40.5 70 73 162 25 58 241 14 104 26 55 M8 x 1.25 Rc 1/4 Bracket Mounting Stroke Long Stroke Without Rear Plate Bracket mounting stroke Stroke range (mm) Bore size (mm) Bore size (mm) Bore size (mm) Y R Z 20 25 32 40 50 20 25 32 40 50 20 25 32 40 50 100 st or more 250 to 400 88 14 119 125 st or more 350 to 500 88 14 131 150 st or more 350 to 600 90 14 136 200 st or more 350 to 800
L 1.25 P=12.5 5.25 7.5 25 35 5.5 1.5 L Dimension L=12.5 x n+10.5 No. L dimension 1 23 2 35.5 3 48 4 60.5 5 73 6 85.5 7 98 8 110.5 9 123 10 135.5 No. L dimension 11 148 12 160.5 13 173 14 185.5 15 198 16 210.5 17 223 18 235.5 19 248 20 260.5 No. L dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No.
force lb (N) Stroke/both Stroke/both Stroke/both Stroke/both Size sides (mm) sides (mm) sides (mm) force lb (N) Basic Compact Basic Compact Basic Compact 10 16 20 25 32 40 10 16 20 25 10 20 32 40 10 20 32 40 1.35 (6) 1.80 (8) 4 6 1.35 (6) 1.80 (8) 4 6 1.57 (7) 16 (32) 24 (48) 32 (64) 40 (80) 1.24 (5.5) 0.79 (3.5) 4 6 8 3.15 (14) 3.15 (14) 6.29 (28) 4.95 (22) 20.2 (90) 3.82 (17) 10 14 22
/4 3/8 1/2 3/4 Size 20 V V Size 30 V V Size 40 V V V Size 40-06 V 3 Modular F.R.L.
E3 ] 23 [AL. 25][AL. 92][AL. 9F] 12.1 1 ON/OFF CYC LS LS0 CYC0 (6 V 3.4 V) LECMR-BAT6V1SET MR-BAT6V1SET (1 pulse/rev) 1 12 2 12. 12.2 (1) LEC-MR-BAT6V1SET 2CR17335A() [V] 6 [mAh] 1650 [] 055 [] 055 [g] 1.2 1ppm Class 9 ( 2g) () 90%RH() [g] 34 32767rev (1) [r/min] 6000 (6000r/min0.2s) (2) 2(20) 2.9(25%20) (4) (3) 5 1. 3000r/min 2.
. 30 10, 20, 30, 40, 50, 75, 100 40 10, 20, 30, 40, 50, 75, 100 Bore size Strokes are available in 1 mm increments by installing spacers in standard stroke cylinders. 10 16 20 25 30 40 10 mm 16 mm 20 mm 25 mm 30 mm 40 mm Port thread type M thread Rc NPT G 10 to 20 Nil 25 to 40 TN TF Series MQQ is not auto switch capable.
_/I41 (* -50 to +85 C Note *) Not allowed with external junction box (J, -40 C) ND9_E1/I09 ND9...E1/I45 -25 to +60 C -25 to +75 C -25 to +85 C ND9_E1/I56 -25 to +60 C -25 to +75 C -25 to +80 C ND9_E1/I32 -25 to +60 C -25 to +70 C -25 to +70 C Table 14 Ambient temperatures, ND9_U 9.2 Installation on a valve controller Variant type IS Class I, Division 1, Groups A, B, C, D, T4...T6 IS Class
(different sides, same side) D-Z73, Z76, Z80 Reed switch 15 25 1pc. D-Y59A(B), Y69A(B), 2pcs. (different sides, same side) 15 25 Y7P(V) 1pc. D-Y7NW(V), Y7PW(V), 2pcs. (different sides, same side) Solid state switch 20 25 Y7BW(V) 1pc. 2pcs. (different sides, same side) 20 30 D-Y7BAL 1pc. Center trunnion is not included.
1, 2 (12) (12) 36 21.5 16.5 19.5 29.5 24.5 100 W W W (12) (12) 32 19 14.5 17 26.5 22 125 (12) (12) 29 17 13 15.5 24 20 150 (12) (12) 35 20.5 15.5 18.5 29 24 25 (12) 24 14 10.5 12.5 10.5 20 16 50 19 11 8 9.5 11 8.5 15.5 12.5 75 3 16.5 9 7 8 9 7 13 10.5 100 14.5 8 6 7 8 6 11.5 9 125 13 7 5 6 7 5.5 10.5 8 150 (40) (40) (40) (40) (12) (12) (40) (40) 25 Type 1 Type 2 Type 3 (40) (40) (40) (12)
Maximum Allowable Load MY3A, MY3B/m1 MY3A, MY3B/m2 MY3A, MY3B/m3 200 50 40 30 100 100 50 40 20 30 50 40 10 20 30 63 63 5 4 20 10 Load weight kg Load weight kg Load weight kg 63 3 40 10 40 5 4 2 3 25 5 4 1 25 40 2 3 25 0.5 0.4 16 2 1 16 0.3 16 1 0.2 0.5 0.1 0.5 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max. MY3A max. MY3B max.
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Port thread type Bore size Symbol Type 6 to 16 M thread Nil Clean series 20, 25 Rc 13 Vacuum suction type (Special treatment on guide) TN 20, 25 NPT TF 20, 25 G MXS 12 13 50 M9N 12 22 50 M9N MXS Number of auto switches Copper, fluorine and silicone-free + Low particle generation Nil 2 pcs.