Tel. +358 20 483 150. Fax +358 20 483 151 North America, 44 Bowditch Drive, P.O. Box 8044, Shrewsbury, M A 01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172 South America, Av. Independncia, 2500-Iporanga, 18087-101, Sorocaba-So Paulo, Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748 Asia Pacific, 238B Thomson Road, #17-01 Novena Square Tower B, Singapore 307685.
Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
D-Y7 W N B D-Y7BA D-Y69 A B D-Y7 WV N B Protrusion [mm] In-line Perpendicular A B D-Y59 O MHW2-20D S 7 12 5 12 12 O MHW2-25D S 7 11 5 10 11 O MHW2-32D S 4 9 2 8 9 O MHW2-40D S 3 8 1 7 8 Hysteresis Switch operating position (ON) O MHW2-50D S 1 6 5 6 Switch return position (OFF) N B D-Y7BA Auto switch model No. Gripper model No.
/30 Dustproof ( DIN terminal, M8 connector conforms to IP65) Enclosure Based on IEC529 Note 1) Based on dynamic performance test, JIS B 8374-1981.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
(15.24/150) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) 10% of rated voltage Allowable voltage fluctuation % Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 3 Note 1) Consult P/A when used under conditions which may cause condensation on the exterior of the product.
Performance Performance data given in this chapter is based on an electrified plate (dimensions: 150 x 150 mm, electrostatic capacity: 20 pF) defined by ANSI standard (ANSI/ESD STM3.1-2006).
[October 2017] B: Contents revised in several places. [July 2018] C: Contents revised in several places. [August 2019] D: Contents revised in several places.
Nil M5 x 0.8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
Referring to case u where "W2" is a sphere, 4a +b 2 2 2 4a +b 2 1 2 1=m1 +m2 12 12 2 r K=m2 5 2 tThin rectangle board (Parallelogram) !0Gear transmission Position of rotation axis: Passes through center of gravity and perpendicular to the board. (Same formula regardless of board thickness.) 1. Find moment of inertia1B around the rod (B). 2.
.*2 Screw-in type Nil Without nozzle 01 Symbol Size Nil Rc3/8 N NPT3/8 F G3/8 50 mm IBG1-12-10-50 02 100 mm IBG1-12-10-100 03 150 mm IBG1-12-10-150 04 300 mm IBG1-12-10-300 11 Long nozzle*1 With S coupler/One-touch fitting 50 mm IBG1-12-10-50S 12 100 mm IBG1-12-10-100S 13 150 mm IBG1-12-10-150S 14 300 mm IBG1-12-10-300S Symbol Applicable tubing O.D. Part no.
Item Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 130 130 (5) Size: Perform setting as shown below.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Nil S n Front nose mount Rear pivot mount Double end mount B C E Nil Without auto switch Auto switch Bore size 3/4" 1 1/16" 1 1/2" 2" 075 106 150 200 For the applicable auto switch model, refer to Best Pneumatics Stroke Hundredths of an inch (i.e. 06 = 0.06") Standard stroke Inches Specifications Specifications 075 (3/4") 200 (2") 106 (1 1/16") 150 (1 1/2") Bore size (in) Fluid Air Maximum
C D Flat Model A E K Model F H J F H J Flat with ribs ZPT40 -B-A14 U C ZPT40D10-B-A14 55 121.5 120 18.5 32 6.5 3.3 40 43 ZPT50 -B-A14 U C ZPT40D20-B-A14 127 65 124 50 19.5 33 7.5 3.8 50 53 137 5 10 6.2 13 ZPT40D30-B-A14 75 134 Dimensions by Stroke ZPT40D50-B-A14 182 95 179 75 1 8 E G: M5 x 0.8 G: Rc 40 50 H J F 40 50 H J F K Model 40 50 U C ZPT 20-B-A14 U C ZPT 30-B-A14 U C ZPT 50-B-A14 U