Auto Switch Proper Mounting Position (Detection at Stroke End) Reed auto switch Solid state auto switch D-A9 D-M9 D-M9W Hs Hs 22 B A 24.5 B A A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch. A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch.

20 0.19 b 0.3 37 30 0.39 b 0.48 19 40 0.79 b 0.8 1.3 1 Compared with existing products (AFFmC, AMmC, and AMDmC series) 2 Compared with existing products (AMFmC series) 50 1.25 b 1.3 4 60 1.50 b 2.0 25 Color-identifiable elements This eliminates the accumulation of condensate.

V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid Temperature Controller Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series

0 100 200 300 400 500 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 300 0 100 200 1.0 VBA VBAT Flow rate (l /min (ANR)) Relief flow rate (l /min (ANR)) Supply pressure P1 (MPa) AP100 557 Series IR1000/2000/3000 Series IR2000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.

A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.

Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.

Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.

Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,

Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).

200 300 300 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MPa 200 200 0.3 MPa 0.3 MPa 100 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) 476 Parallel Style Air Gripper: Wide Type Series MHL2 Model Selection

B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)

For details on how the models are indicated, refer to How to Order. 315 or more 50 200 or more 63 CCT63 120 or more 80 75 or more 100 1164 Air-hydro Unit CC Series Data (A) Volume of Cylinder/Capacity of Converter 160 140 125 100 800 700 600 300 250 200 180 10,000 8,000 500 400 80 6,000 5,000 4,000 300 600 500 63 3,000 200 400 50 2,000 300 40 Effective oil level stroke (mm) 500 200 1,000

C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.

B' B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Drain guide R, NPT, G Operating Pressure: 0.5 (MPa) Operating pressure: 0.5 (MPa) Mounting bracket Port size Model E M3 x 0.5 Depth 8 Drain piping D C B A F G H J K B' 3 8 AMC310 75 140.5 138.5 150.5

C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.

C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.

Tube bore size B, #2(#2+#3) 40 125, 150, 175, 200, 250, 300 55 14 14 3.8-9 Series CXT Auto Switch Specifications Refer to p.5.3-2 for details on auto switch.

port B 2 A 4 Indicator light 6 A 4 B 2 A B 5 SMC SMC SMC SMC SMC A A A A A B B B B B Manual override B 2 A 4 A B A B A A B 4 L2 L1 B 2 A 4 3 B 2 A 4 2 34.5 48 68.5 P = 41 58.5 P = 41 B 2 A 4 1 X 12 Stations R4.5 D side 107.8 179 (Single, Double, 3 position, Rubber type) 184.5 (3 position, metal type) 15.5 17 22 51 69 117 2-Rc 1/8 (External pilot port) With connector on D side (FD) 2-6-12

Series VXH 2 3 4 Class 2 Class 3 Class 4 Material and insulation type VXF Symbol Nil D H N Coil insulation type Seal material Body material Class B Class H Class B Class H Stainless steel Brass (C37) Valve type VX3 FKM N.C. 2 VXA 1 Thread type VCHm 1 Rc NPT G Nil N F VDW Voltage 1 2 3 4 5 6 7 8 J 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 240 VAC 48 VAC 230 VAC VQ Port size LVM Class B

It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.