The AFW is available for US and Canadian customers only.8 threaded models to 1,500 SCFM (3"NPT), Three filtration/coalescing grades available as well as activated carbon, Differential pressure indicator and float type auto drains are standard, Modular connectivity permits compact assembly , 232 psi max. operating pressure, FILTER, 450 SCFM, 2.0 NPT, 0.01 MICRON, FILTER, L25, 4.9 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, K40, 450 lb
Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., Valve, Media, 2 PORT VALVE, K80, 450 lb
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 450
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 450
Please contact us for the latest version.sales@ocaire.com, 5M CC-Link 82 Deg Angled Cable, SERIAL TRANSMISSION SYSTEM, 645, 450 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, K40, 450 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.C., 3 PORT SOLENOID VALVE, K44, 450 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.C., 3 PORT SOLENOID VALVE, K44, 450 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.O., 3 PORT SOLENOID VALVE, K44, 450 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.O., 3 PORT SOLENOID VALVE, K44, 450 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.O., 3 PORT SOLENOID VALVE, K44, 450 lb
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 450
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 450
three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 450
.): ø1/4" / ø5/16" / ø3/8" / --, Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 250 / 450 / 550 / 650, Flow Rate (Vacuum Pressure) [L/min]: 30 / 70 / 80 / 100, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 1260,
.): ø1/4" / ø5/16" / ø3/8" / --, Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 250 / 450 / 550 / 650, Flow Rate (Vacuum Pressure) [L/min]: 30 / 70 / 80 / 100, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 1260,
.): ø1/4" / ø5/16" / ø3/8" / --, Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 250 / 450 / 550 / 650, Flow Rate (Vacuum Pressure) [L/min]: 30 / 70 / 80 / 100, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 1260,
.): ø1/4" / ø5/16" / ø3/8" / --, Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 250 / 450 / 550 / 650, Flow Rate (Vacuum Pressure) [L/min]: 30 / 70 / 80 / 100, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 1260,
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, COM, 3 PORT SOLENOID VALVE, K44, 450 lb