Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.
D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in styles other than those mentioned in Note 1. 12 Auto Switch Mounting Series CJ2Y Operating Range Auto Switch Mounting Brackets/Part No.
Note 4) ( ): Dimensions for D-A93. Specific Product Precautions Be sure to read this before handling. Mounting Caution Appropriate tightening torque 1. Observe the proper tightening torque in the right table in mounting.
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols
Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not
Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.
Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
Applicable models: D-A73, A73H, D-A93, A93V 2) Note however, that in the case of 2 color indicator type auto switches (D-A79W), if the wiring is reversed, the the switch will be in a normally ON condition.
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12
Note 3) ( ) in column W is the dimensions of D-A93.
Note 4) Figures in ( ) in the table W are D-A93.
The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZ's unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating, double power cylinder with rod-side end lock, Bore sizes (mm): 40, 50, 63,
The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZ's unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating, double power cylinder with rod-side end lock, Bore sizes (mm): 40, 50, 63,
The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZ's unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating double power cylinder, Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, Standard
CHQ CHK CHN Mounting correctly Mounting incorrectly CHM CHM CHS
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.