Mounting: Basic Style, Bore Size: 20mm, Port Thread: 20 & 25 Bore: M5 x0.8, 32-50 Bore: Rc Thread, Stroke: 350mm, Option: Rear Plate, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Mounting: Basic Style, Bore Size: 20mm, Port Thread: 20 & 25 Bore: M5 x0.8, 32-50 Bore: Rc Thread, Stroke: 200mm, Option: Rear Plate, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Mounting: Basic Style, Bore Size: 20mm, Port Thread: 20 & 25 Bore: M5 x0.8, 32-50 Bore: Rc Thread, Stroke: 75mm, Option: Rear Plate, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series ZPT ZPX Related 25 50 75 100 Equipment Pad Material and Characteristics Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Durometer HS (5C) Material 50C 50C 50C 60C 60C NBR 0 to 120 30 to 200 0 to 60 0 to 250
Parts Description w r LED indicator q No. Description Contents q Nozzle Discharge ionized air w Slide cover Protective cover for the mode setting switch e Mode setting switch Switch for setting blow and trigger (Default setting: Set no. 0) e r Flow adjustment knob (With indicator) Turn the knob to adjust the flow rate.
OUTLET INLET Mounting hole Top view (Mounting hole on bottom) Porting Symbols OUTLET (Downstream) INLET (Upstream) 2PW 2PWA 2PWC q q q w 2 PORTS w w 3PWD 3PWE 3PWG 3 PORTS q q q e e e w w w 4PWM q e r 4 PORTS w 1114 A
Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3
Bit: 7 0 Byte 1 Offset Baud rate (Communication speed) (bit/s) 500 k 250 k 125 k 50 k 20 k 10 k 1 M 800 k Bit: 7 0 Byte 2 Offset Max. bus cable length (m) 25 50 100 250 500 1000 2000 5000 Power supply wiring Power supply connector Bit: 7 0 Byte 3 Offset M12 5-pin plug B-code (reverse) Bit No. 0 2 4 6 0 0 4 6 No. Description Function Output No.
Material Note Description Body Needle Bottom cover Handle Component Parts Chromated Aluminum alloy Brass Aluminum alloy Zinc alloy q w e r No. Description Material Note Body Valve guide Check valve Needle Handle Chromated Chromated Rubber lining Chromated Black painted Aluminum alloy Aluminum alloy Brass Brass Carbon steel q w e r t AS Replacement Parts ASP No. Description Part no.
A G Dimension table G 1/8 1/4 F 12 14 E 4 6 D 10 12 C 23.8 24.5 B 40.8 44.5 A 37 42 Model G3601 G4602 Specifications G3601 R 1/8 G4602 R 1/4 270 Rolled steel plate (black melamine coated) Polycarbonate Brass 55g 80g Model Piping port size Scale angle Case Installing the Cover After setting the indicator needles, return the cover to its original position by aligning the indentation at the
(A) 2 0.7MPa (101psi) 0.15MPa (22psi) 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa (145psi) 0.05MPa (7psi) Fluid AM150 AM250 Maximum operating pressure Rated flow rate (ANR) 300l/min (10.5SCFM) 750 l/min (26.5SCFM) Note 1) Series AM separates and removes the oil mist in compressed
(A) 2 0.7MPa 0.15MPa 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa 0.05MPa Fluid AM150 AM250 Maximum operating pressure Rated flow rate l/min (ANR) 300 750 Note 1) Series AM separates and removes the oil mist in compressed air which is troublesome for ordinary filters, and removes fine
(A) 2 23 (AR) (A) 2 Refer to Best Pneumatics No. 1 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Regulator Series AR Model Specifications Model AR20 Port size 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 AR40 AR20 AR25 AR30 AR40 Model Proof pressure 1.5 MPa 1.0 MPa 0.05 to 0.85 MPa 1/4, 3/8, 1/2 Max. operating pressure Pressure gauge port size 1/8 1/4 Set pressure range Ambient and 5 to 60C (No freezing
Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used. Area x Pressure = Force Output Example: What is the theoretical force output of a 2 12 bore cylinder operating at 80 lbs. per square inch air pressure? Step 1.
Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used. Area x Pressure = Force Output Example: What is the theoretical force output of a 2 12 bore cylinder operating at 80 lbs. per square inch air pressure? Step 1.
Color KK130 T0604-250-X64 T0604-500-X64 200 200 475 475 52 52 120 200 5.1 9.4 Black, White D1 DM KDM KB D2 D3 W KR KA KQG2 KG KFG2 MS KKA KP LQ MQR T T IDK 463
(A) 2 0.7MPa 0.15MPa 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa 0.05MPa Fluid AM150 AM250 Maximum operating pressure Rated flow rate l/min (ANR) 300 750 Note 1) Series AM separates and removes the oil mist in compressed air which is troublesome for ordinary filters, and removes fine
IFW520 125 VAC 10 to 20 25 1.5 or less 5 5 1.5 0.7 4 4 2.5 1.3 IFW550 250 VAC 20 to 50 60 3 or less 5 5 1 0.5 4 4 1.5 0.8 Note) Hysteresis is the flow rate that is necessary for moving the microswitch from the operation position (ON signal) to the return position (OFF signal). 8 VDC 7 5 3 3 5 4 3 3 5 5 3 3 4 4 3 3 14 VDC 30 VDC 5 5 3 3 4 4 3 3 125 VDC 0.4 0.4 0.1 0.1 0.4 0.4 0.1 0.1 250 VDC
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500