SMC Corporation of America
Elite Part Number Search
Search Results "MBD80-200Z-NW"

Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 150mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: N (Pivot Bracket)

Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 700mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)

Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)

Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 50mm, Cushion: N (w/o Air Cushion), Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

pressure Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1 14 45 Leakage Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation Flange type KF(NW

25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114 30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW

Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1) 5 14 45 80 Internal 1.3 x 10-10 for the standard material (FKM) Leakage at ambient temperatures , excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW