SMC Corporation of America
Elite Part Number Search
Search Results "LEJS40S2A-1200-S2"

Magnet: None, Mounting: C (Single Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: None, Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 4 pcs., Stroke Options: XC10 (Dual Stroke, Double Rod)

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Magnet: None, Mounting: L (Foot), Bore Size: 325 (3 1/4"), Stroke A: 1200 (12"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1200 (12"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

1800 2400 3000 0 1200 2400 3600 4800 6000 Flow [L/min] Flow [L/min] Flow [L/min] 11 3-Color Display Digital Flow Switch for Large Flow PF3A7 H Series IN Side Straight Section and Accuracy (Reference Data) PF3A703H (for 3000 L/min) PF3A706H (for 6000 L/min) PF3A712H (for 12000 L/min) 70% 70% 70% PFG300 Function Details PF3A7 H With 1/2" connected With 1" connected With 1 1/4" connected 60%

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

0.3 0.4 0.6 0.5 0.8 0.7 0.9 1000 1.0 Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) IR2120-02 IR2120-02 IR2120-02 Supply pressure: 1.0 MPa Back pressure: 1.0 MPa 1.0 0.8 0.204 0.9 0.7 0.8 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) 0.6 0.202 0.7 Set point 0.5 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200

VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer N AN210-02 AN101-01 AN120-M5 14-10-3 4 Series VY1 Characteristics SignalOutlet Pressure Characteristics (Characteristics of pressure setting) VY1A00 1/1B00 1 1 VY1100 1/1200

Air Flow characteristics Min. operating pressure differential (MPa) Orifice size (mm) Model Air Water Flange Thread Max. system pressure (MPa) Weight (g) Oil AC DC AC DC AC DC 1.0 1.0 1.0 1.0 32A 40A 50A 1 VXD2260-10 VXD2270-32 VXD2380-40 VXD2390-50 25 35 40 50 0.02 0.03 0.03 0.03 225 415 560 880 13 23 31 49 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.7 0.7 0.7 0.7 0.7 310 550 740 1200

IN Model/Valve Specifications Connection Max. operating pressure differential (MPa) Flow characteristics Water, Oil Weight (g) Min.operating pressure differential (MPa) Orifice size (mm) Max. system pressure (MPa) Model Thread Water Oil Cv converted Av x 10 -6 (m 2) 1 2 3 4 VXR2150-04 VXR2150-06 VXR2260-10 VXR2270-12 VXR2380-14 VXR2390-20 20 20 25 35 40 50 1250 160 180 290 530 720 1200 6.5

S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1. Material HNBR: Nitrile hydride rubber 500 700 500 1000 1500 800 1000 1200 1000 500 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 500l/min (ANR) is P = 0.64MPa for a 3 orifice, and P = 0.35MPa for a 4 orifice.

Minimum sensing weight after balancing Minimum sensing weight = Cylinder friction + Valve error + Exterior guide friction Cylinder friction Cylinder minimum operating pressure x piston area Valve error = VY 1200 sensitivity ( 0.01MPa) x pistion area Refer to the data of the respective guide for the friction of the exterior guide.

Thomas Oil-less WOB-L Piston Compressor Flow Rate: 12.7 LPM , 12.7 LPM, Max Pressure: 17.4 PSIG / 1200 mbar , 17.4 PSIG / 1200 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 5.71 in / 145 mm Width: 2.48 in / 63 mm Height: 4.09 in / 104 mm , Length: 5.71 in / 145 mm, Width: 2.48 in / 63 mm, Height: 4.09 in / 104 mm, Net Weight

Thomas Oil-less WOB-L Piston Compressor Flow Rate: 12.7 LPM , 12.7 LPM, Max Pressure: 17.4 PSIG / 1200 mbar , 17.4 PSIG / 1200 mbar, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 5.71 in / 145 mm Width: 2.48 in / 63 mm Height: 4.09 in / 104 mm , Length: 5.71 in / 145 mm, Width: 2.48 in / 63 mm, Height: 4.09 in / 104 mm, Net Weight

Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 5.5 LPM , 5.5 LPM, Max Pressure: 17.4 PSIG / 1200 mbar , 17.4 PSIG / 1200 mbar, Max Vacuum: 23 in HgV / -780 mbar , 23 in HgV / -780 mbar, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 4.29 in / 109 mm Width: 2.4 in / 61 mm Height: 3.27 in / 83 mm