SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25S2A-200-S5A1"

C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2 LECSN2-T-P 200 to 240 Nil Without cable H Without cable Connector only 1 1.5 [m] Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -9- AC servo motor LECY* series L E K F S

DC Red Black 100 VAC Blue Blue 2 200 VAC Red Red 2 (, +) Other AC Gray Gray With surge voltage suppressor With surge voltage suppressor There is no polarity for DC. (For the low power consumption type, there is polarity.) Description Part no. Seal VCW20-15-6 Note) Please order separately.

VY1 Connected to VBA20A, 40A VBAT20A1 VBA VBAT VBA VBAT Material: Carbon steel Connected to VBA22A, 42A AP100 Tank IN port Rc 1/2 Booster regulator IN port Booster regulator IN port Tank OUT port Rc 1/2 C C Spare port Rc 1/2 EXH: C EXH: C (A) (B) (A) D (B) OUT OUT 305 180 206 206 4 x 13 4 x 13 50 50 200 100 100 400 Drain port Rc 1/4 200 674 (mm) D Note) 469 493 685 A 481 520 444 477 B 394

a=3000 L1 mm L1 mm L1 mm Vertical Horizontal Lateral Horizontal/Lateral W a=2000 a=2000 a=2000 a 200 200 200 a=1000 a=3000 a=3000 L3 M3 0 5 10 15 0 2 4 6 8 10 0 5 10 20 15 Work load (W) kg Work load (W) kg Work load (W) kg 600 600 600 a=1000 a=3000 a=1000 400 400 L3 mm L3 mm L3 mm a=2000 a=2000 a=2000 400 a=3000 a=3000 a=1000 a 200 200 200 L1 M1 0 2 4 6 8 10 0 5 10 20 15 0 5 10 15 Work load

U (mm) Operating pressure Air pressure compact cylinder 1 MPa or less Model Applicable bore size (mm) Applicable cylinder nominal thread size Rotating angle Compression side Tension side JB12-3-050 JB16-4-070 JB20-5-080 JB25-6-100 JB40-8-125 JB63-10-150 JB80-16-200 12 M3 x 0.5 112 112 0.5 Operating range Center of sphere 16 M4 x 0.7 200 200 0.5 Axial center Operating range 20 M5 x 0.8 1100

Effective after being energized for more than 200 ms when the voltage is applied 1. Power saving circuit The power saving circuit (PWM control) built into the product reduces power consumption via high-speed switching operation with the PWM control circuit after the rated voltage has been applied for approx. 200 ms when energized.

50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 1000 1000 100 80 500 400 300 500 400 300 63 100 100 80 50 40 80 200 200 63 63 100 100 Load weight: m (kg) Load weight: m (kg) 50 50 50 40 30 50 40 30 40 40 20

U (mm) Operating pressure Air pressure compact cylinder 1 MPa or less Model Applicable bore size (mm) Applicable cylinder nominal thread size Rotating angle Compression side Tension side JB12-3-050 JB16-4-070 JB20-5-080 JB25-6-100 JB40-8-125 JB63-10-150 JB80-16-200 12 M3 x 0.5 112 112 0.5 Operating range Center of sphere 16 M4 x 0.7 200 200 0.5 Axial center Operating range 20 M5 x 0.8 1100

(3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 CLQ 100 500 400 300 500 400 300 80 MLGP 100 63 200 200 50 40 80 RLQ Load weight: m (kg) Load weight: m (kg) 100 100 63 50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P

250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure

SQ1000 12ms or less 200 million cycles The 3 port valves on the A and B sides can operate independently. SQ2000 20ms or less Model JIS symbol A side B side When used as 3 port valves, only half the number of stations is required.

A 2 to 200 L/min flow range option has been added. A rear ported type has been added. A flow adjustment valve (0.05 to 5 L/min) has been added.

A: Orange B: Green 110.5 100 84 13 148 137.5 116 16 160.5 150 132 14 173 162.5 148 12.5 198 187.5 164 17 210.5 200 180 15 223 212.5 196 13.5 235.5 225 212 11.5 (Station n) (Station 1) Block separation lever (Push type) (DIN rail dimension) SS5X5-45Stations BC4 C6 C8 (Pitch) P = 16 DIN rail release button 2n-One-touch fittings 4-One-touch fittings (A, B port) Applicable tubing O.D.: (P , R

] 400 400 500 mm stroke or less m 300 300 L5 600 mm stroke or less 600 mm stroke 200 200 100 100 0 0 Work load [lb] 0 2.2 4.4 6.6 8.8 11 Work load [lb] 0 2.2 4.4 6.6 8.8 11 300 300 250 250 Overhang: L6 [mm] Overhang: L6 [mm] 500 mm stroke or less 200 200 600 mm stroke or less m L6 150 150 100 100 600 mm stroke 50 50 0 0 Work load [lb] 0 2.2 4.4 6.6 8.8 11 Work load [lb] 0 2.2 4.4 6.6 8.8

*Power supply 100 V type: 35C Power supply 200/230 V type: 40C 2.

Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.

, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.

Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.

master unit) Power supply DC24V Battery LE-MR-J3BAT (accessory) Encoder cable Standard Robot Absolute Encoder (SSCNET III) option USB cable LEC-MR-J3USB Setup software Driver Main circuit power connector (accessory) Prepared by user (MR Configurator2TM) LEC-MRC2 Power supply 1-phase 100 to 120VAC (50/60Hz) 200 to 230VAC (50/60Hz) 3-phase 200 to 230VAC (50/60Hz) option PC Regenerative option

to 230 200 to 240 200 to 230 200 to 240 200 to 240 200 to 240 200 to 240 200 to 240 A1 LECSA1-S A 10 A2 LECSA2-S * The length of the encoder, motor and lock B2 LECSB2T cables are the same.