LFE14(Z) 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE26(Z) 62 53 4.6 9.5 14 56 38 2.5 depth 8.5 2.6 Approx. 70g LFE38(Z) 62 53 4.6 3.5 20 68 43 2.5 depth 8.5 2.6 Approx. 70g NOTE) If you are installing directly, choose the self tapping screw in depth is to 8mm.
Contact input signal 2 type Setting and checking 39. Press the [SEL] key once. The set screen of contact input signal 2 type is displayed on the digital display. PV SV 40. Select contact input signal 2 type from the table below with [] key or [] key, and confirm by pressing SEL.
Contact input signal 2 type Setting and checking 39. Press the [SEL] key once. The set screen of contact input signal 2 type is displayed on the digital display. PV SV 40. Select contact input signal 2 type from the table below with [] key or [] key, and confirm by pressing SEL.
HRL Series 5.4 Description of the Screen 5-39 HRX-OM-Y098 Chapter 5 Display and Setting of Various Functions (1) (2) (3) (4) TEMP READY signal (AL16) setting Table 5.4-11 TEMP READY signal setting No.
50 70 183 80 31 75 52 77 29 10.5 XMC-63 88 209 100 39 87 114 95 70 76.5 36 9 P.C.D 92.1 8x8.4 XMC-80 90 250 117 45.5 114 110 83 105 44 9 9 XM-OMP0002-A 4-3.
Comm Format: Data-SINT Comnection Parameters Instance Size Input 100 256 Output 150 256 Configuration 1 0 It is not necessary to set Connection and ModuleInfo. RSLogix5000TM is a registered trademark of Rockwell Automation. 20 - 5. External connection 5. 1 CN4: Power supply connector Connect the power supply. The gateway unit and the controller (LEC) should have the common 0V line.
14 port side SOL 12 port side SOL Pin no. 1: Open 2: 12 port side SOL (+) 3: COM () 4: 14 port side SOL (+) 5: Ground ZNR ZNR 4 2 2 4 5 DC: Double 3 3 Solenoid Valve (with M Connector) Comforming to ISO 15407-1 Series EVS1-01/1-02 Dimensions EVS1-01-FG-S-M0 117.5 75.5 27.5 (14 port) 27.5 (12 port) 10.5 (4 port) 10.5 (2 port) 14 4 2 12 12 26 35 45 14 Indicator light 5 1 3 Manual override 39
Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions . Series AS-FG Speed Controller with One-touch Fittings Stainless Series In-line Type.
14 port side SOL 12 port side SOL Pin no. 1: Open 2: 12 port side SOL (+) 3: COM () 4: 14 port side SOL (+) 5: Ground ZNR ZNR 4 2 2 4 5 DC: Double 3 3 Solenoid Valve (with M Connector) Comforming to ISO 15407-1 Series EVS1-01/1-02 Dimensions EVS1-01-FG-S-M0 117.5 75.5 27.5 (14 port) 27.5 (12 port) 10.5 (4 port) 10.5 (2 port) 14 4 2 12 12 26 35 45 14 Indicator light 5 1 3 Manual override 39
Station n L1 L2 Station 2 35.5 28.5 Station 20 224.5 217.5 3 46 39 4 56.5 49.5 5 67 60 6 77.5 70.5 7 88 81 8 98.5 91.5 9 109 102 10 119.5 112.5 11 130 123 12 140.5 133.5 13 151 144 14 161.5 154.5 15 172 165 16 182.5 175.5 17 193 186 18 203.5 196.5 19 214 207 1-5-20 4/5 Port Solenoid Valve Rubber Seal Series SYJ3000 C4 N3 Type 32 Manifold: Side Ported/SS5YJ3-32Stations -M5, [ ]: AC (Lead
It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.
L1 L2 L3 L1 L2 L3 L1 L2 L3 VXE21 VXE22 VXE23 Manifold construction 2 stations x 1 3 stations x 1 2 stations x 2 2 stations + 3 stations 3 stations x 2 2 stations x 2 + 3 stations 2 stations + 3 stations x 2 3 stations x 3 2 stations x 2 + 3 stations x 2 (mm) Electrical entry W Conduit terminal T DIN terminal T Conduit R Grommet Model A B C D E F H J N X 69.5 72.5 75 Y 100.5 103.5 106 V 39
Refer to pages 17-3-38 and 17-3-39 for specifications and models.
Straight portion length 1/8" 6 1/4" 8 10 12 Nylon tubing Soft nylon tubing Polyurethane tubing 44 or more 84 or more 89 or more 112 or more 140 or more 168 or more 16 or more 30 or more 32 or more 40 or more 50 or more 60 or more 25 or more 39 or more 57 or more 52 or more 69 or more 88 or more 29 or more 39 or more 56 or more 58 or more 70 or more 82 or more 4.
(SeeLECSS Operation Manual (Simplified Edition),section 6.3.2 for uploading.) -39- 6.7.2 To Load saved Parameters From the Parameter Setting window in the setup software, select Open. Please specify location of the file. Please select the file from which you wish to import parameters [.prm2]. Click Open.
17 Installation 17 Piping 20 Wiring 22 Outline of Settings [Measurement mode] 24 Pressure Setting 25 3 Step Setting Mode 26 Simple Setting Mode 28 Function Selection Mode 30 Function selection mode 30 Default setting 30 F 0 Display units, switch output specifications and diagnostic information selection function 32 F 1 Setting of OUT1 34 F 2 Setting of OUT2 37 F 3 Digital filter setting 39
19 19 39 64.9 73.5 49.5 39 M10 x 1.5 12 20 LD LW MM M N L P PA PB Q QW R T TA TB W WA WB Y Z Model CYP15 5.6 69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".
14 port side SOL 12 port side SOL Pin no. 1: Open 2: 12 port side SOL (+) 3: COM () 4: 14 port side SOL (+) 5: Ground ZNR ZNR 4 2 2 4 5 DC: Double 3 3 Solenoid Valve (with M Connector) Comforming to ISO 15407-1 Series EVS1-01/1-02 Dimensions EVS1-01-FG-S-M0 117.5 75.5 27.5 (14 port) 27.5 (12 port) 10.5 (4 port) 10.5 (2 port) 14 4 2 12 12 26 35 45 14 Indicator light 5 1 3 Manual override 39
Setting/Checking: Contact input signal 2 type 39. Press the [SEL] key once. Setting screen of contact input signal 2 type is displayed on the digital display. PV SV 40. Select contact input signal 2 type with [] key or [] key, and press [SEL] key to enter.