/Program No. selection 1 5 DI0 19 20 LZR LZ Encoder Z -phase pulse 23 DI1 Point table No.
+ Stroke H K F T T V V 2-Rc P Cushion adjustment screw 4-J GA F GA A MA a A MA a Air release R (max.)
L3 d1 H9 MB1 Part no. d3 h KJ27D KJ36D KJ42D M27 x 2 M36 x 2 M42 x 2 110 125 142 70 80 90 37 43 49 51 56 60 4 4 4 36 41 46 125 160/200 250 30 35 40 CA2 CS1 C76 C85 C95 CP95 NCM NCA D-X 20Data 6-12-39 40 Refer to Page 6-16-1 for details on auto switches.
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire (NPN equivalent) Reed switch Solid state switch A96V A96 IC circuit 5 V Grommet Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV
D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length. (Example) Nil Lead wire length 0.5 m 3 m L 5 m Z None N Applicable for the connector type (D-C) only. Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-A73(C)(H)/A80C Solid state switch: Manufactured upon receipt of order as standard.
16 11 13 11 Vacuum supply port 3.3 Gasket Vacuum supply port 3.3 Gasket 16-6-12 7 Compact Pressure Switch Series ZSE2/ISE2 01 T1 Dimensions: ISE2Grommet type: ISE2-15 01 T1 01 T1 Connector type: ISE2-15C Pressure setting trimmer Pressure setting trimmer L H SET L H SET 15 15 ZSE ISE Indicator light (Red) Indicator light (Red) 20 20 PSE Z I SE3 600 (3000) PS 600 (3000) Z I SE1 2 Courtesy
80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz 41-122 F (5-50C) 22psig (0.15MPa) 150psig (1.0MPa) () 36-104 F (2-40C) (85%) () 1 AC115V10% 60Hz (Note3) (2)
Z S L, Z S Note ) PAX 1 1 4 1 2 PB AC Ordering example (Example) Series VXR21, Rc 3/4, 24 VDC, Conduit terminal (Part no.)
Nil R Internal pilot External pilot R U S Z NS NZ For K and H, mounting screws do not fall out from the valve.
tubing 6/4 Y C Q V BB W K H IN OUT IN OUT Z P2 (Pressure gauge port size) Pressure gauge (Option) 2 x P1 (Port size) Plate thickness 10-/21-AW30K-B: Max. 3.5 10-/21-AW40K-B: Max. 5 B Hexagon width across flats 17 Clearance for maintenance G 1/4 Drain E CC A AW60K-B 1021S N T D J J M U Applicable tubing 6/4 R C Q BB K H IN OUT P2 Pressure gauge (Option) 2 x P1 (Port size) (Pressure gauge
175, 200, 250, 300 44 11 11 3.8-8 Platform Cylinder Series CXT 32, 40 (N) S+Stroke X+Stroke H 4-M8 X 1.25 4-8.7 Through, Counter bore 14 Depth 8 HP Depth 12 HG 12 Back side 4-M10 X 1.5 Depth 15 (N) T PA T CL d d MLGC RW RW CNA M20 X 1.5 CB QW PW GP PB W E CV/MVG Y Z CXW 2-Rc(PT)1/8 CXS CXT G G 2-RB2015 (Option) 2 HT F MX A L HN (MAX.)
Cap Cap bracket RE A B REC CX CY MQQ M (mm) Model Basic type With cap With cap Basic type dimensions h Hexagon nut F MM H 2.4 2.4 2.7 2.7 a 5 6 6 7 E1 2.8 2.8 3 3 D M8 x 1.0 M8 x 1.0 M10 x 1.0 M10 x 1.0 E2 L LL S E3 LL Z B C RHC RB0805 RB0806 RB1006 RB1007 RBC0805 RBC0806 RBC1006 RBC1007 1.4 1.4 1.4 1.4 6.8 6.8 8.8 8.8 6.8 6.8 8.6 8.6 33.4 33.4 39 39 45.8 46.8 52.7 53.7 40.8 40.8 46.7 46.7
Cap MI W S Cap bracket CEP1 CE1 CE2 ML2B C J G5-S (mm) CV Model Basic type With cap With cap Basic type dimensions h Hexagon nut D M14 x 1.5 M14 x 1.5 M20 x 1.5 M27 x 1.5 E1 5 5 6 8 E2 K 11 12 15 25 L LL S E3 LL Z B C H 3.5 3.5 4 5 MM F MVGQ RBC1411 RBC1412 RBC2015 RBC2725 RB1411 RB1412 RB2015 RB2725 12.2 12.2 18.2 25.2 12 12 18 25 12 12 18 25 58.8 58.8 62.2 86 78.3 79.3 88.2 124 67.3 67.3
YES Hysteresis mode OFF n_1 n_2 Large pressure and vacuum pressure [n] H (Fix hysteresis) = 3 digits H H ON Window comparator mode NO OFF n_1 n_2 Large pressure and vacuum pressure 16-2-30 7 Series ZSE50F/ISE50 High Precision, Digital Pressure Switch for General Fluids Example of Internal Circuit and Wiring ZSE F/ISE --22(L)-(M) 50 60 50 60 ZSE F/ISE --30(L)-(M) 50 60 50 60 With analog
Z DO W Note 1) Refer to Table (1) on page 378 for combinations with electrical entry.
Calculate the load factor for each direction. x = Xc/Lx, y = Yc/Ly, z = Zc/Lz 5. Confirm the total of x, y, and z is 1 or less. x + y + z 1 When 1 is exceeded, please consider a reduction of acceleration and work load, or a change of the work load center position and series. Acceleration [mm/s2]: a Work load [kg]: m Work load center position [mm]: Xc/Yc/Zc z y 1. Horizontal 3.
Yaxis [Axis speed calculation] Composite travel distance = Target position 1 2 Z Z Y Y X X 2 2 2 Composite speed 1 2 1 2 (X2, Y2, Z2) Xaxis speed = ( 1 2 X X / Composite travel distance) Composite speed Y axis speed = ( 1 2 Y Y / Composite travel distance) Composite speed Z axis speed = ( 1 2 Z Z / Composite travel distance) X axis Composite speed Current position (X1, Y1, Z1) Z
A : Max. 3.5 AR20-A to AR25-A : Max. 4 AR30-A to AR40-06-A : Max. 8 Model Standard specifications Optional specifications Round type pressure Round type pressure gauge gauge (with color zone) Bracket mount Panel mount P1 P2 A B C D F J H J H J M N Q R S T U V W Y Z AR10-A M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5 26 26 25 28 30 4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22
The length (Dimension S) is 25.5 when any of the following grommet type auto switches are used: D-R73/R80/S79/S7P/T79 The length (Dimension S) is 34.5 when any of the following connector type auto switches are used: D-R73/R80/T79 (mm) A B C D E (g6) F (h9) G H K L M N R S1 S2 T U V W X Y Z Model CDRBU2W15-D 5 0.004 0.012 6 0.004 0.012 8 0.005 0.014 12 0 0.043 14 0 0.043 16 0 0.043 34 25 29
Knuckle Pin (Common with double clevis pin) Rod End Nut d d Dd9 C m l L t m t H B Material: Carbon steel Material: Carbon steel Part no. Applicable bore size (mm) 20 25 32, 40 50, 63 80 100 Applicable bore size (mm) Snap ring l D d H B C Part no.