SMC Corporation of America
Elite Part Number Search
Search Results "HRSH250-AN-20-AS"

Auto switch reset position (OFF) Protrusion of Auto Switch from Edge of Body The maximum protrusion of an auto switch (when fingers are fully open) from the edge of the body is shown in the table below. Use the table as a guideline for mounting. MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used.

Stroke ST (mm) 0 4 6 8 10 15 20 Caution Stroke ST (mm) When driving an inertial load, operate a cylinder with kinetic energy within the allowable value.

An element service indicator is fitted as standard. The new red ring is larger than the existing indicator, which improves visibility. The time for replacement can be checked visually. New element Element requiring replacement An end cap with slits is used for the element. Can be identified by color The type of element can be identified by the color of the end cap.

No.8 Function UNIT STATUS GW status information isn't sent to master side as an input data. OFF OFF ON GW status information is sent to master side as an input data. HOLD/CLR UNIT STATUS ON Address HW/SW : If the address setting is turned on, an input setting for PLC is required.

dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2

The allowable load mass and maximum operating pressure should be as shown in the table below. The cushion effect (smooth start-up, soft stop) is not available an intermediate stop or return from an intermediate stop using an external stopper, etc.

Do not apply strong impact or an excessive moment while mounting a workpiece. LC3F2 If an external force over the allowable moment is applied, it may cause play in the guide or an increase in the sliding resistance. 5. The forward/reverse torque limit is set to 100% (3 times the motor rated torque) as default. 9. Keep the flatness of mounting surface 0.1 mm or less.

Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 4-4-25.) 4-4-20 21 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.

Hysteresis angle: Value of auto switch hysteresis converted to an angle. Note) Since the above values are only provided as a guideline, they are not guaranteed. In the actual setting, adjust them after confirming the auto switch operating condition.

85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC side pressure (kPa) Flow rate (l/min (ANR)) 14-5-20 20 Series IRV1000/2000/3000 Made to Order Specifications: Please contact SMC regarding detailed dimensions, specifications, and delivery times. 1.

Clean Series (10-Series) Copper-free Series (20-Series) Clean Series products are those which can be used in cleaner environments, such as in clean rooms, as compared to a general factory environment. For further details, refer to the Clean Series catalog.

Front matter 7 Flow Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to front matter pages 1 to 6.

Therefore, avoid using the product in environment where corrosive gases are present as much as possible. 2) Do not scratch the coated surface of the copper tube when removing the panels for maintenance. As the corrosion resistance can be deteriorated from the scratch position.

Nil S n L Auto switch type Nil Without auto switch Cylinder bore size (stroke mm) Refer to the table below for auto switch part numbers. 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil F R Note 2) Standard With buffer With

Necessary counter-measures for possible lightning surge should be fitted to system components as required. 5. Do not operate in locations having an atmosphere of flammable, explosive or corrosive gases, which can result in fire, explosion or corrosion. The air catch sensor does not have an explosion proof rating.

Cannot be used as an emergency shutoff valve, etc. 3. Countermeasures against static electricity The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted.

Piping materials without flexibility such as steel tube piping are prone to be effected by excess moment load and vibration from the piping side. Use flexible tubing in between to avoid such an effect. As a filter is a heavy object, please transfer or install it making sure that it will not be dropped or dented.

Bore size(mm) 12 12mm 32 32mm Port thread type Auto switch 16 16mm 40 40mm Nill M5X0.8 12,16 Nill Without auto switch 20 20mm 50 50mm Rc Solid state M9B , M9BW 20 to63 25 25mm 63 63mm TN NPT Read switch A93 TF G *The minimum stroke autoswich Mounting and operating range are the same as standerd product. 2.

When not using this product as a replacement for HRG/HRGC, this function is not needed.

25 20 20 20 1 1 10 100 50 51 200 10 100 50 51 200 Stroke (mm) Stroke (mm) (19) L = 50 mm, V = 400 mm/s (20) L = 100 mm, V = 400 mm/s 100 100 63 63 50 50, 63 50, 63 50 10 10 40 40 Load mass m (kg) Load mass m (kg) 40 40 32 32 32 32 25 25 25 25 20 20 20 20 1 1 0.1 0.1 10 100 50 51 200 10 100 50 51 200 Stroke (mm) Stroke (mm) 508 Model Selection MGPW Series L L m m Horizontal Mounting Ball