SMC Corporation of America
Elite Part Number Search
Search Results "HRSH150-W-40-K"

Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 4 0.5 0.5 4 3 16 16 2 2 40 40 5 5 2 1 Pin no. Pin description 1 DC(+) 2 NC/Analog output 3 DC() 4 OUT 31

Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W

DC AC, DC 60 40 1 80 60 10(1) 40 60 60 40 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.

(REFRIGERANT) IDF60-20) W R 0001 (2018 4 ) W R 0001 2018 2019 2020 2021 W X y Z 1 2 3 4 o P Q R o 1 Z 12 A Z IDF60/70/80/90 Series 1-5 IDX-OM-W093 1.3 HFC 1-5 IDF60/70/80/90 Series 1-6 IDX-OM-W093 1.4 / 1 1.5 () IDF60/70/80/90 Series 1-7 IDX-OM-W093 IDF60/70/80/90 Series 1-8 IDX-OM-W093 2 2.1 IN OUT (ONOFF ) 6-4 6-4 IDF60,70,80,90-20 IDF60,70,80,90-30 AC200V AC200V L1 L2

Problem 3 Red ON OFF Red Flashing W-SS W-SS LED flashes red or orange or is off Problem 4 Orange Flashing OFF Green Flashing Red Flashing Red ON W-NS W-NS LED does not turn on green. Problem 5 Red Green Alternate Flashing OFF Red Flashing W-MS W-MS LED does not turn on green.

L N PFMB7501/7102 70 30 43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0001CN-F (ZS-33-D) (ZS-33-F) -68No.PF-OMP0001CN-F Revision history A B C D E F [September 2016] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com

Standard Strokes Bore sizes (mm) Standard strokes (mm) 20 & 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Pages 22 to 24 Manufacture of Intermediate Stroke Cylinders Hydraulic Fluid Compatibility Intermediate strokes in 5mm increments can be manufactured by installing spacers

High voltage type (1.0 MPa) Negative COM External pilot Low wattage type (0.5 W) Nil K N R Y D: Slide locking type (Manual) Note) A B 4 2 C Seal Note 2) 1 5 3 0 1 Metal seal Rubber seal N.C N.O P EA EB Note 3) 3 position closed center Note) For rubber seal type only.

NBR JIS B2401G35 1 pc. u 4.6-30 Series AMF Dimensions: AMF150 to AMF350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4,3/8 1/4, 3/8 5.5 6 6 7 7 139 152 158 184

l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than

Load Load Load Load Load 1.2 k N.C. 7.3 k Auto shift input (Yellow) DC (+) Sensor input: +1 to 5 VDC DC () CH1_OUT1 (Black) Pressure is applied to a pressure sensor during the reset operation (a zero point adjustment) as follows: When compound pressure is used: 2.5% F.S. or more. When pressure other than compound pressure is used: 5% F.S. or more.

weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

For sonic range Where P1 = 0.10132 (P2 + 0.1013) Formula based on Cv factor Q = 98.9Cv (P1 + 0.1013) kg/h Formula based on effective area Q = 5.5S (P1 + 0.1013) kg/h 1 5 20 3 4 20 1 0 30 40 30 20 40 20 30 30 40 20 50 60 60 50 40 30 20 3 4 30 40 50 Figures inside [ ] indicate the saturated steam holding heat (kcal/kg). Figures inside ( ) indicate the saturation temperature (C).

In the case of w/indicator light, avoid damaging the indicator light with lead wire. (Voltage symbol) Refer to the table below. (Position for light mounting) Terminal block Terminal screw (3 locations) Tightening torque 0.2 to 0.25 Nm Shaved part Precautions Plug a connector in or out vertically, never at an angle.

AC (3) Nil Standard type No High pressure type (Metal seal only) (1.0 W) K (1) Yes Yes (W/o indicator light) Yes (W/o indicator light) (0.5 W) Y Low wattage type External pilot type R (2) Note) Standard lead wire length: 300 mm.

VZ (A) 2 (A) 2 VS 3 (R) 1 (P) 3 (R) 1 (P) r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts Material Description Notes No.

140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator