How to Use L/M Plug Connector Manual Override Caution Warning Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Non-locking push type (tool required) is standard. Locking type (tool required) is available as an option.
Secure the switch at an appropriate position with a flat head watchmakers screwdriver as indicated in Figure 3. Tightening torque: 0.05 to 0.1 Nm Second groove MRHQ 10, 16 3. Install the switch case, with a switch attached securely in the hole, in the direction indicated in Figure 1.
I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03 KFT10U-04 KFT10N-02 KFT10N-03 KFT10N-04 KFT12U-02 KFT12U-03 KFT12U-04 KFT12N-02 KFT12N-03 KFT12N-04 29 34 32 37 53 49 50 56 46 49 54 46 63 90 57 62 88 79 81 94 75 78 93
Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 8.) 3 Series SYJ300 Construction (A) 2 (A) 2 N.C.
Concave top ex) wVNH13 is not available to use as 2 port valve by plugging B port.
If the effective area is smaller, it may encounter an unexpected sudden slide table movement. Install a solenoid valve for braking as close to the cylinder as possible. If there is a long distance between the cylinder and valve, it may cause fluctuations in the stop accuracy or unexpected sudden slide table movements.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
If the effective area is smaller, it may encounter an unexpected sudden slide table movement. Install a solenoid valve for braking as close to the cylinder as possible. If there is a long distance between the cylinder and valve, it may cause fluctuations in the stop accuracy or unexpected sudden slide table movements.
Orifice Fittings Many of our small brass fittings such as B1, B2, T1, T2, etc., are available as orifice fittings. In the case of Tees, the branch and/or one end of the run may be an orifice. A cross can have as many as three orifices. The general dimensions in this catalog are subject to change without notice 5/32 Couplings 7/16 1/2 15/16 1 5/16 5/16 Typ.
Male threads 17 : 3/8-16 45 : 2-12 78 : M18 x 1.5 cannot be specified equal to, but 18 : 3/8-24 46 : 2 1/4-12 79 : M18 x 2.5 19 : 7/16-14 47 : 1 7/8-12 80 : M20 x 2.0 not, greater than the rod diame20 : 7/16-20 48 : 2 3/4-12 81 : M20 x 2.5 ters as standard. 21 : 1/2-13 49 : 3-12 82 : M22 x 1.5 22 : 1/2-20 50 : 3 1/4-12 83 : M22 x 2.5 23 : 9/16-12 51 : 3 1/2-12 84 : M24 x 2.0 24 : 9/16-18
Mounting switch at the edge of response range could Loading time (ms) result in an unstable response. Wiring/current and voltage 1. Ensure that the load is connected before connecting the power SOu rce. 2. Use as short a wire as possible. Using a long wire to reach the load could increase the inrush current when the switch is on and consequently shorten the switch life. 3.
Manual Override Connection and Electrical Circuit Warning Connect each lead wire to the power source side, because of no polarity for DC as well. Black (DC) Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option.
the model to process an air flow larger than 412 l/min IDF11C is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2.
The connection method is as above. 1 If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. Connector pin No.
The connection method is as above. 1 If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. Connector pin No.
equipment such as a voltmeter.
Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 4. After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. 5. When changing the detecting position, carry out in the state of 3. 1.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
When exhaust piping is connected to the exhaust port (3), select a model with an effective sectional area not smaller than that in the table below. 1. Use clean air. Do not use compressed air which contains chemicals, synthetic oils containing organic solvents, salts or corrosive gases, etc., as this can cause damage or malfunction. 2.
This regulator cannot be used as a check type regulator to be installed between a solenoid valve and an actuator. It can cause breakdown and malfunction. 7.