To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder. 4. Note that the stopping accuracy will be influenced by changes in piston speed.
To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder. 4. Note that the stopping accuracy will be influenced by changes in piston speed.
This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.
4 (A) 4 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) How to Order Manifold Base 2 position double 2 position double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the
In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible. To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder. 1.
This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.
Now with a snap shot function for set value reading Snap shot function Pressing the and buttons simultaneously for a minimum of 1 second will make the set value (threshold value) the same as the current pressure value.
When a load such as a relay or solenoid which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.
Manifold base recommended dimensions Lead wire Base mounting hole 1 (IN) 2 (OUT) 1 (IN) 9.5 or more Valve mounting pitch 2 (OUT) A A M3 x 0.5 Thread depth 5 2 (OUT) port 1 (IN) port 3 M3 x 0.5 Thread depth 5 Electrical entry can be on the either side, right or left. 2 (OUT) port 3 11 11 40 Sectional view A-A (2:1) 4 4 46 or more RZ12.5 1 (IN) port 510 High Speed 2 Port Valve SX10 Series Control
side and then B side in that order as shown in the figure a.
Manufacturer M4 x 0.7 M3 x 0.5 Thread size 32.5 21.5 Effective thread length (mm) 8 6 Quantity 2 4 P.C.D. 46 45 Motor mounting area When mounting a coupling on the motor, mount it within the dimensional range shown on the left. A A B Section BB P.C.D.
Connect the skip valve to the A port side of a stop valve as in the case of the speed control valve.
How to Order 1F 06 T 200 AS Flow Direction Symbols on Body JIS Symbol Symbol Tamper proof Note) Speed controller requires a special tool for flow adjustment. Order separately with part number, AS-T-1.
With a model that has the maximum flow rate line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. AFF AM Misc. Inlet pressure (MPa) 14-20-43 3 Series AMF Flow Characteristics/Refer to How to Select on page 14-20-43 regarding model selection.
When not using this product as a replacement for HRG/HRGC, this function is not needed.
When not using this product as a replacement for HRG/HRGC, this function is not needed.
If the valve has been used outside of the specifications, or if a failure occurs as a result of mounting onto a machine or replacement of an assembly, seals, or etc. by the user, the warranty will not be applied. Note) The endurance of the product will depend on the operating conditions (such as if the flow rate is large).
In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible. To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder. 8.