SMC Corporation of America
Elite Part Number Search
Search Results "CLA2F100-700-D"

When locking the manual override with the push-turn locking type (D or E type), be sure to push it down before turning. Turning without first pushing it down can cause damage to the manual override and other trouble such as air leakage, etc.

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC Manifold. 700 lb.

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC MANIFOLD. 700 lb. VVM.

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC MANIFOLD. 700 lb. VVM.

Base mount, plug-in manifold for VQC1000 valve, Conforms to IP40, D-sub connector reduces labor while minimizing wiring and saving space, 25 pin D-sub connector that conforms to MIL standards, Maximum 24 stations available as standard, Optional DIN rail mount, 21 port sizes available 4/5 PORT SOLENOID VALVE. VQC Manifold. 700 lb.

(LJ1S Series only) C D Running accuracy Model C plane to A plane D plane to B plane LJ1H10 LJ1H20 LJ1H30 LJ1S10 LJ1S20 LJ1S30 0.07 or less 0.03 or less 0.09 or less 0.12 or less 0.1 or less 0.1 or less 0.07 or less 0.06 or less 0.03 or less 0.015 or less 0.1 or less 0.1 or less B A Actuator control Programming from a PC Programming and start-up: easy programming is possible by means of the

weight Space saving, light weight 50 40 46 33 60 74 LTF8 work piece mounting section dimensions LTF6 work piece mounting section dimensions 412mm 4.6kg 1000mm Values of the horizontal mounting type with standard motor and 100 mm stroke 357.5mm 2.2kg 600mm Overall length Weight Maximum stroke Table traveling accuracy Table traveling accuracy Lead screw Ground ball screw Rolled ball screw C D

(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.

Inlet side air (HOT AIR) Push button switch Pilot light Fan motor Model Selection (Flow Capacity l/min (ANR)) Outlet thermometer Model HAA7 HAA15 HAA22 HAA37 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 7000 Inlet air temperature Outlet side air (COOL AIR) 4300 Conditions: Outlet temperature 40C, Ambient temperature 32C, Air pressure 0.7 MPa Cooling side air Cooler Drain

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]

Magnet: None, Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]