(mm/s) : Distance to the load's center of gravity (m) : Dynamic moment (Nm) : Gravitational acceleration (9.8m/s) m FE ME L1 3 1.4 100 1 3 Note 4) a is a dimensionless coefficient for calculating impact force.
Ground the F.G. cable with a resistance of 100 or less +24 V Brown + 24 VDC +24 V Blue 0 V Power supply 24 VDC 0 V F.G.
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).
The following graphs show the displacement at point A, which is 100 mm apart from the center of rotation, where the load is applied.
HS 8.5 SMC SMC SMC SMC 16 16 A 29 Auto switch B A 26 Auto switch B (36) D-B5/B6/B59W type 20 to 40 D-G5NTL type 20 to 40 50 to 100 50 to 100 Approx. HS Approx. HS 12 12 SMC SMC 24.5 24.5 A 33 B A 33 Auto switch B D-C73C/C80C type 20 to 40 D-H7C type 20 to 40 50 to 63 50 to 63 Approx. HS Approx.
200 300 500 700 Average speed Va mm/s A, A Stroke (mm) A A A A 20 14.5 16.5 21 27 29.5 35.5 Model 150 56.5 64 125 42.5 55 64 100 34 42.5 53.5 50 75 28.5 34 33 37.5 43 50 18.5 28 25 30 33.5 43 40 18.5 20.5 25 27 29.5 35.5 30 14.5 18.5 21 27 29.5 35.5 10 14.5 16.5 21 27 29.5 35.5 Allowable moment coefficient: Graph 2 MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 6 7 9 10.5 14 16.5 13.5 16 19.5 24.5
200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Ex. 1) To detect 300 m, select a 1.0 detection nozzle and supply pressure of 0.2 MPa.
Single vane type Double vane type , 0 5 Chamfer +4 0 a a r r n n 9 0 n n e g g 0 o o g e e i i n t t 1 2 a a 0 a 8 7 t t r o o 1 +4 0 0 0 n R R o e +4 0 +4 0 i t g 0 a n 9 t o a e r R g n n o a ti r a n t o o R ti a t o R Chamfer Chamfer Chamfer Chamfer A port B port A port B port A port B port A port B port For size 40 actuators, a parallel keyway will be used instead of chamfer.
The switch may be damaged if a screw other than the one supplied, is used. 100 A or less at 24 VDC Leakage current 0.8 mA or less Operating position . Red LED lights up Optimum operating position .
One-touch fitting One-touch fitting A A 58 Applicable tube O.D.
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
Set of long clamping screws ZH2-TB203-A 3 M4 x 70 2 pcs. ZH13DA ZH15DA ZH2-TB204-A 4 M4 x 90 2 pcs. ZH2-TB206-A 6 M4 x 130 2 pcs. Hexagon nut (M4) 2 pcs. ZH2-TB208-A 8 M4 x 170 2 pcs. (ZH2-TB201-A)3 1 M4 x 30 2 pcs. Flat washer (for M4) 2 pcs. ZH2-TB302-A 2 M4 x 55 2 pcs. ZH2-TB303-A 3 M4 x 80 2 pcs. ZH18DA ZH20DA ZH2-TB304-A 4 M4 x 100 2 pcs. ZH2-TB306-A 6 M4 x 145 2 pcs.
Bore size/ Standard stroke (mm) Auto switch Nil Without auto switch (Built-in magnet) Auto switches are shipped together (not assembled). 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 A + Stroke B + Stroke Dimensions (mm) A B GB Bore size (mm) 40 63 100 58 48.5 36.5 GB 73 61.5 38 78 66.5 38 Dimensions other than the above are the same as standard products.
A 2 to 200 L/min flow range option has been added. A rear ported type has been added. A flow adjustment valve (0.05 to 5 L/min) has been added.
The amount of grease per cylinder of 100 stroke is shown in attached table 10. Roughly, one scoop with a forefinger is approximately 3g. Grease in the groove Grease on the outer A little less than 1mm.
Port size port 3(R) port 1(P), 2(A) Body size Rated voltage (Only with solenoid) 04 06 10 10 12 14 20 1 2 3 4 1 2 100 VAC 50/60 Hz (Ex.)
97 10 FV FV M 25 10 to 50, 75, 100 104.5 12 CC 28 10 to 50, 75, 100 124 12 L FT FX B + Stroke FZ FX (Dimensions except A and L are same as rod side flange style.)
97 10 FV FV M 25 10 to 50, 75, 100 104.5 12 CC 28 10 to 50, 75, 100 124 12 L FT FX B + Stroke FZ FX (Dimensions except A and L are same as rod side flange style.)