SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2KB12-15DCZ-A96"

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0300 (3"), Cushion: w/o Rubber Bumper, Auto Switch: A96--Reed, DC Volt, LED, Horizontal

Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0300 (3"), Cushion: w/o Rubber Bumper, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

(m) () AC 0.5( ) 1(M) 3(L) 5(Z) DC 3(NPN) M9NV M9N 3(PNP) M9PV M9P 2 12V M9BV M9B 5V12V IC 3(NPN) M9NWV M9NW 3(PNP) M9PWV P9PW 2 12V M9BWV M9BW IC 5V12V (2) PLC 24V 3(NPN) M9NAV M9NA 3(PNP) M9PAV M9PA 2 12V M9BAV M9PB (2) 2( ) P4DW IC 5V12V (2) (NPN) 5V A96V A96 IC 100V A93V A93 PLC 12V 24V 2 100V A90V A90 IC 18-2. 0.5m ) M9NW 1m M ( M9NWM D-P4DW32100 3m L (M9NWL 5m Z (M9NWZ

(P.29~32) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.

(P.20) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Note 1) For the tightening of the mounting screws (M2.5), use a precision screwdriver with a handle diameter of approximately 5 to 6 mm.

(P.27 to 29) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.

1) Auto switch with an indicator light (Except D-A96 , A96V) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to the internal voltage drop in the auto switch specifications.)

Electrical entry Electrical entry WiringOutput Indicator Applied load 0.5 3 5 DC AC Vertical Horizontal Nil (L) (Z) 3 wires 5V A96V A96 IC circuit Equivalent to NPN Presense Grommet A93V A93 Relay 100V wires 24V PLC Nil 5V,12V 100V or less IC circuit A90V A90 24V 5V,12V M9NV M9N wiresNPN) M9PV M9P wires(PNP) 24V M9BV M9B wires Relay 24V PLC Grommet Presence 5V,12V F9NWV F9NW wiresNPN