SMC Corporation of America
Elite Part Number Search
Search Results "CDJ5D16SR-30-B"

68.6 D D B 2 S B 2 B 2 B 2 B 2 1 P P 1 A 4 A 4 A 4 A 4 A 4 * These figures show the JJ5SY3-10F2-05DR-C8.

Bonnet assembly/construction part number:1 Indicator Flange (valve) size 16 25 40 50 With XLA16-30-1H-F7// XLA25-30-1H-F7// XLA40-30-1H-F7// XLA50-30-1H-F7// Without XLA16A-30-1H-F7// XLA25A-30-1H-F7// XLA40A-30-1H-F7// XLA50A-30-1H-F7// Indicator Flange (valve) size 63 80 100 160 Without XLA63-30-1H-F7// XLA80-30-1H-F7// XLA100-30-1H-F7// XLA160-30-1H-F7// With XLA63A-30-1H-F7// XLA80A-30

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -39No.PS-OMV0009-E [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

Cylinder stroke 30 40 30 mm (50, 63) Flange side Auto switch 40 mm (80) Nil Nil Without auto switch (Built-in magnet) Action D B T For applicable auto switches, refer to the table below. Auto switches are shipped together, (but not assembled).

30 d d C D C D H B H B Part no. d H B C D Applicable bore size (mm) Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 26 32 38 41 13 17 22 24 10 Series CHN

size 63 80 100 160 General use without XLF63-30-1 XLF80-30-1 XLF100-30-1 XLF160-30-1 with XLF63A-30-1 XLF80A-30-1 XLF100A-30-1 XLF160A-30-1 High temperature without XLF63-30-1H XLF80-30-1H XLF100-30-1H XLF160-30-1H with XLF63A-30-1H XLF80A-30-1H XLF100A-30-1H XLF160A-30-1H Note1) The magnet for auto switch is not provided.

30 d d CHQ C D D C CHK H B B H Material: Carbon steel Material: Carbon steel CHN Part no. d H B C D Applicable bore size (mm) NT-02 NT-03 NT-04 AC-NI-50 Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 CHM CHM 8 8 9 11 5 6 8 10 12.5 16.5 21.0 23 20 25 32 40 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 26 32 38 41 30 36.9 43.9 47.3 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5

Grease pack GR-L-005 (5g) GR-L-010 (10g) GR-L-150 (150g) 6 Microspeed Cylinder: Standard/Double Acting: Single Rod Series CQ2X 32, 40 The dimensions are the same as the standard double acting single rod cylinder; refer to the series CQ2/CDQ2 section in Best Pneumatics No. 2 How to Order B 40 30 D CQ2X Without Auto Switch With Auto Switch CDQ2X A73 B 40 30 D Number of auto switches With auto

Note 2) Min. operating frequency is once in 30 days. (Based on JIS B 8375) Note 3) Based on dynamic performance test, JIS B 8375-1981.

A2 Bracket B (Part no.: ZS-46-A2) The bracket configuration allows for mounting in four orientations. 30 25 20 45 5.2 30 9.1 13.6 1.6 5.2 5.2 22 7.2 7.2 20 * When using the bracket B, install it by taking the dimensions of the piping part into consideration. 16 ZSE20(F)/ISE20 Series Dimensions Panel mount adapter ZSE20(F) ISE20 Option 2 B Panel mount adapter ( Part no.: ZS-46-B) 47.8 50.8

(16.3) 10 (7) 5.5 20.8 56.2 35 17.2 PE X DIN rail B A B A B A B A B A B A 9.9 Manual override (Locking type: Press, then rotate.)

U D-A79W D-F7WV D-F7V D-F7BAVL A B A B Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V D-F7W, D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-F7F D-F9BAL D-A79W D-F7NTL Bore size (mm) A B A A A A B A A A B B B B B B 20 20.5 11.5 21 18 25 26 12 9 16 17 32 27 20 27.5 24.5 31.5 26 19 30 29 32.5 20.5 17.5 24.5 23 22 25.5

D1: max. diamet 30 Series KQ2 One-touch Fittings Extended male elbow: KQ2W Inch size tube/metric thread (formerly IQ) e l b a c i l p p A . D .

0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility water temperature Facility water temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35

(per 1 m3) The amount of water at the intersection C the amount of water at the intersection H = the amount of condensed water 18.2 3.0 = 15.2 g/m3 Dew Point Conversion Chart 60 50 40 30 20 Pressure dew point (C) B A 10 1.5 MPa 1.3 MPa 1.1 MPa 0.9 MPa 0.7 MPa 0.5 MPa 0.3 MPa 0.1 MPa Atmospheric pressure 0 -10 -20 -30 -40 -50 C -60 -50 -60 -20 -10 0 10 20 30 -40 -30 Atmospheric pressure

1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective area

W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for

port M5 x 0.8 Operation direction A (Plug: M-5P) 49 46 38 5 22 12 19 4 40 25 Y Y 5.5 Operating port M5 ~0.8 24 84 Operation direction B (Plug: M-5P) Operation direction B A 7 6.5 13 10 10 13 A 14.8 30 7 24 A 15.8 Z Cross section AA (scale 50%) (N-1) x H G H 6 depth 4.5 5H9 +0.03 N-M4 x 0.7 thread depth 8 0 Bottom through hole 3.3 5H9 +0.03depth 4.5 0 F E Model J N H G F E Z MXW8-25 64 3

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).