(mm) Bore size A1 82 85 MM M6 x 1.0 M8 x 1.25 20 25 B1 10 13 C1 10 12 H1 3.6 5 K 5 5 KA 6 8 L1 22 24 X 12 14 (mm) Bore size A 70 71 H M4 x 0.7 M5 x 0.8 20 25 B 60 61 C 8 10 D 8 10 E 33 40 F 6 6 I 42 50 K 5 5 KA 6 8 L 10 10 M 22 26 N 4.4 5.4 OA M5 x 0.8 M6 x 1.0 Q 14 14 R 10 10 SA 6.5 6.5 SB 10.5 11 Stroke range 50 or less 50 or less Note 1) The [ ] value denotes dimensions with the auto
Settable range : 10...1999 (1.0 kPa...199.9 kPa) Combination conditions with other parameters : 10 H3 P3-1 (10) ... ... ... ... ... 16 2 R/W 0x000A Release confirmation hysteresis (H3) of CH15 (10) Note At Pressure P1/P2, set the negative pressure (vacuum pressure) in units of -0.1 kPa. At Pressure P3, set the positive pressure in units of -0.1 kPa.
) 2-3.2 equivalent (18.5) A B 1.5 11 17.5 Manual override A B 1.5 33 16 (18.5) (21) 18.9 13.5 15 54.5 Manual override 21.6 54.5 28.5 2-1 (Bleed port) 21 R2 P P1 P R R (11) (0.5) 13 10 5 2-1 (Bleed port) M5 x 0.8 (Piping port) 10 10 7 7 14 M3 x 0.5 28 (Piping port) 5-2-21 4 4/5 Port Air Operated Valve Series SYJA5000 How to Order A, B port size Bracket One-touch fitting for 6 C6 One-touch
(Page 73) Only when a temperature sensor is connected. 2011 0x07DB 0 R Temp.
L R L R L R L R L R L R Glass q w e Stainless steel Stainless steel Cross recessed round head screw Brass Stainless steel r t Stub 3.8-2 ISA Specifications Fluid Dry air (Filtered through a 5m filter) Operating pressure range 0.05 to 0.2MPa Recommended pressure range 0.1 to 0.2MPa Detection zone 10 to 300 m Repeatability including temperature characteristics 10m (for 0 to 60C on the basis
10 10 11 D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W D-G79/K79/K79C Since this is a guideline including hysteresis, not meant to be guaranteed.
Type 40/Type 41 How to Order SS3YJ7-40 -05 --01 Applicable solenoid valve SYJ714SYJ714MSYJ724SYJ724MApplicable blanking plate assembly SYJ700-10-2A R port 1/4 R port 1/8 P, R port thread type Manifold type Stations 40 41 Type 40 Type 41 Nil Rc G NPT NPTF 2 stations : 20 stations 02 : 20 F N T A A A A 01 1/8 A port size P port 1/8 P port 1/4 A port 1/8 Note) If there are more than 6 stations
Existing model 15 10 Heating functions are required to maintain a constant temperature particularly in the winter when the ambient temperature is low. 5 0 0 5 10 15 Time [Minute] Anti-freezing function is also available!
Note2) Only PFA is applicable as a body material. Note 2) A R P N.C. 3 port PA N.C. 17-5-5 3 Series LV Manually Operated Series LVH P. 17-5-27 Integral Fitting Type Model LVH20 4 4, 6 1/8, 3/16, 1/4 LVH30 8 6, 8, 10 1/4, 3/8 LVH40 10 10, 12 3/8, 1/2 Orifice diameter Tubing O.D. Metric Inch Symbol Type Valve type Basic type N.C. A B A B Non-locking Locking Manifold (5 stations max.)
size P A Q R Conduit T DIN terminal Conduit terminal E D B C F H N.C.
Dust proof filter set (A) (25) (25) (B) (10) Part No.
Dimensions inch (mm) AK3542 & 4542 M5 x 0.8 Actuation port 1.57 (40) 2.24 (57) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: N, BRN Connections: 4T, 6T Connections: 4, 6, BR 4 6 4 6 4 6 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Construction Solenoid Valve Type Air Operated Type VXF2 A<A<r r w w e e q q VXF2 A<A<r r w w e e q q Component Parts Component Parts No.
Connection threads R/NPT W M L E W H A Model E L A M LQ3H11-M LQ3H12-M LQ3H21-M LQ3H22-M LQ3H31-M LQ3H32-M LQ3H33-M LQ3H34-M LQ3H35-M LQ3H36-M LQ3H38-M LQ3H41-M LQ3H42-M LQ3H43-M LQ3H44-M LQ3H51-M LQ3H52-M LQ3H53-M LQ3H61-M LQ3H62-M LQ3H63-M 4 3 10 11 33.5 10 29.5 14 28.5 9 32.5 1/8" 39.5 37.5 38.5 36.5 1/8" 1/4" (E,E) Port size R (NPT) 6 17 16 43.5 14 20 16 42.5 10 8 10 8 10 51 48 1/8" 55
Base mounted Common EXH 2 to 20 stations 5 (R) , 3 (R) port 1/4 VPA P.1512 VFA330 VPA3 1 (P) port 1/4 VFA5000 VV5FA5-20 4 (A), 2 (B) port Common EXH 2 to 10 stations 5 (R) , 3 (R) port 3/8 1 (P) port 3/8 VFA520 VV5FA5-21 4 (A), 2 (B) port 5 (R) , 3 (R) port 1/2 Common EXH 2 to 15 stations 1 (P) port 1/2 VFA3000 VV5FA3-40 5 (R) , 3 (R) port 1/4 Common EXH 2 to 20 stations VFA340 1 (P) port
MA a CHM A MA a Cushion adjustment screw Air release R (max.)
(mm) Weight (g) Thread R(PT) H (Hex.) M5 A D1 L1 D2 M L2 Part No.
E MGPL (ball bushing)/Dimensions A, E (mm) (mm) E E A 10 to 39st 43 49 A Bore size (mm) Bore size (mm) 10 to 74st 42 46 75 to 100st 60.5 64.5 101 to 250st 85 95 10 to 74st 0 0 75 to 100st 18.5 18.5 101 to 250st 43 49 40 to 100st 55 65 101 to 250st 85 95 10 to 39st 1 3 40 to 100st 13 19 101 to 250st 43 49 12 16 12 16 A E A E Bore size (mm) Bore size (mm) 20 to 74st 53 53.5 75 to 200st 84.5
Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.