This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, GA, AL MASS PRO 3/4 MODULAR (PT), 2.77782 lb
The AL bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.?The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment., LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, GA, AL MASS PRO 3/4 MODULAR (PT), 3.30693 lb
The AL bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment., LUBRICATOR, LUBRICATOR, MODULAR F.R.L., 0.94 lb
The AL bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment., LUBRICATOR, LUBRICATOR, MODULAR F.R.L., FVD, 0.94 lb
Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 678 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.
(A)4 2(B) (A)4 2(B) 4(A) 2(B) (EA)5 1 3(EB) (EA)5 1 3(EB) (P) (P) 3-position pressure center 5(EA) 3(EB) 1(P) (A)4 2(B) N.O. valve x 2 pcs. 2(B) 4(A) (EA)5 1 3(EB) (P) 3(EB) 5(EA) 1(P) N.C. valve, N.O. valve x 1 pc. of each 2(B) 4(A) 3(EB) 5(EA) 1(P) Component Parts No.
When resuming the operation after resetting the alarm, make a home position return. 3 36 3.
Warning reset SigmaWin+ SigmaWin+ Power [Alarm] [Setup] Warning Number Warning Name Alarm warning OFF clear command [Display Alarm] [Software Reset] [ALM-CLR] ON Reset button Execute button A.900*3 Position Error Overflow A.901*3 Position Error Overflow Alarm at Servo ON A.910*3 Overload A.911*3 Vibration A.920*3 Regenerative Overload A.921*3 Dynamic Brake Overload A.930*3 Absolute Encoder
Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.
(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.
A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
mm 47.6 mm UN-2A NPTF 3 Piece Design Port 2 A B Part Number A B Wrench Flats Dia.
(inch) 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 7/8" Applicable tubing size (mm) 6 x 4 10 x 8 8 x 6 12 x 10 19 x 16 25 x 22 No. 2 3 3 4 5 6 Size Symbol 2 3 4 5 6 A A A A A 1 1 2 1 1 1 Dimensions Space saving run tee: LQ3T-SR Metric Size F (E,E) Applicable tubing O.D.
Transporting and Installation . 3-1 3.1 Transporting . 3-1 3.1.1 Transporting with forklift . 3-2 3.1.2 Transporting with caster . 3-3 3.2 Installation . 3-3 3.2.1 Installation conditions . 3-4 3.2.2 Installation location and maintenance work area . 3-5 3.3 Procedure for Installation . 3-6 3.3.1 Installation . 3-6 3.3.2 Procedure for product securing . 3-6 3.3.3 Wiring installation . 3-7
HEP Related How to Order Equipment S 0X 15 ZSP1 Piping specifications Model Other caution Grommet (0.6 m) Grommet (3 m) Connector (0.6 m) Connector (3 m) Nil Applicable model Symbol PV, V port size Caution It might not be possible to successfully pick a workpiece if a picking nozzle or a picking pad that is out of the applicable range is used.
Proper Mounting Auto Switch Position (Detection at stroke end) 16 to 25 Auto switch (Sensor section) 22 Indicator light B A 21.6 11 22 U Bore size (mm) U B A 16 23.5 5.5 8 64.5 4 20 25.5 7 8 Auto switch (Amplifier section) 25 28.5 7.5 8 Lead wire length D-F7NJL: 3 m D-F7NJZ: 5 m Lead wire length: 3 m 32 to 63 U A 21.6 B Lead wire length: 3 m Auto switch (Amplifier section) Indicator light
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
VBAT-V1 PVQ VY1 The Accessory Kit is a Set of Nos. q to r. VBA VBAT VBA VBAT VBAT5A-Y-3 VBAT10A-Y-3 VBAT20A-Y-3 VBAT5S-Y-4 VBAT10S-Y-4 VBAT20S-Y-4 Quantity No.
Message frame . 3-7 3.9 Function code . 3-9 3.10 Checksum calculation method . 3-9 3.10.1 LRC(ASCII) . 3-9 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code: 04 Reading multiple registers .3-12 3.11.2 Function code: 06 Writing registers.3-13 3.11.3 Function code: 16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register map . 3-18
N.O. 1 (P) 5 (R1) 3 (R2) 3 position exhaust center 4 position dual 3 port valve (A) 4 position dual 3 port valve (C) (A) 4 (B) 2 4 2 4 2 5 3 1 5 3 1 1 (P) 5 (R1) 3 (R2) N.C. N.O. N.C.