actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200
VK Applicable solenoid valve Type 25 (Non plug-in type) How to Order D 25 05 00C VV4Z1 VZ 4(A), 2(B) port G L M D G L M D VZ1120-M5 Stations VF VZ110-M5 (3 port valve) 02 2 stations 1(P), 3(R) port One-touch fitting for 6 VFR Applicable blanking plate assembly VZ1000-10-2A 20 20 stations SUP/EXH block mounting position VP4 DIN rail length specified B D U Both sides: 2 to 20 stations D side
L With surge voltage suppressor H 100 VAC J 110 VAC K 200 VAC L 230 VAC M Conduit terminal 24 VDC With surge voltage suppressor N 100 VAC P 110 VAC Q 200 VAC R 230 VAC S Conduit 24 VDC With surge voltage suppressor T 100 VAC U 110 VAC V 200 VAC W 230 VAC Faston terminal Y 24 VDC Z Other voltages For other special options, refer to pages 20 and 21. 24 VAC 48 VAC 220 VAC 240 VAC 12 VDC Special
NBR/POM A With A Direct piping type 40A 24 VDC 50A A B Direct piping type B C D E F G H J K L M N P Q R S T U V W 65A 5 100 VAC Grommet Flange type with surge voltage suppressor 110 VAC A B C D Direct piping type 200 VAC Flange type 230 VAC 80A 6 Flange body I type 24 VDC Flange body II type 24 VDC DIN terminal with surge voltage suppressor 100 VAC 7 8 90A B Flange type 110 VAC 100A 200
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFMB7, Flow Rate Range: 10 to 1000 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: -, Bracket: -, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 20 to 2000 L/min, Thread Type: Rc, Port Size: 3/4, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: -, Bracket: -, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: -, Bracket: -, Calibration Certificate: -
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series
Cooling tower 127 P Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) P Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series,Water-cooled/HEC001-W, HEC003-W) P Suitable to fluorinated fluids (Fluorinert TM FC-3283, GALDEN HT135) (Water-cooled/HEC006-W, HEC012-W) P Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, HEC003-
thread u r y e w e y q y u r y e w u i t q i t q i t q r y e w AS e w q w ASP o Free flow Female thread Male thread ASN Free flow One-touch fitting Male thread AQ ASV AK Component Parts ASS Description Material Note No.
2.5 10 m 1.2 Response time (sec) Response time (sec) 8 m 2 0.9 5 m 8 m 1.5 0.6 5 m 1 3 m 3 m 0.3 0.5 1 m 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 1 m 0 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Detection distance (mm) Detection distance (mm) Piping tubing lengthResponse time Piping tubing lengthResponse time Nozzle Shape Please keep the nozzle shape as illustrated below.
Construction Meter-out type Meter-in type AS1200M AS2200M AS1210M AS2210M u w u w t e r !
Piping tubing length 0.4 0.8 Response time (sec) Response time (sec) Piping tubing length 10 m 0.3 0.6 8 m 8 m 5 m 0.2 0.4 5 m 3 m 3 m 0.1 0.2 1 m 0 0 0.35 0.05 0 0 0.16 0.02 0.3 0.25 0.2 0.15 0.1 0.14 0.12 0.1 0.08 0.06 0.04 Detection distance (mm) Detection distance (mm) Piping tubing lengthResponse time Piping tubing lengthResponse time Nozzle Shape Please keep the nozzle shape as illustrated
Temperature With Thread B W/O Thread IEC Standard IP67, JIS0920 (Water Proof, Oil Proof) Housing S T R O K E Bore Size Stroke mm (inch) inch 6 (1/4) 1/4, 3/8, 1/2, 3/4 10 (3/8) 1/4, 3/8, 1/2, 3/4, 1, 1-1/4 15 (5/8) 1/4, 3/8, 1/2, 3/4, 1, 1-1/4 D I M E N S I O N S N O S E M O U N T: NCJPB S Y M B O L S S Z With Auto Switch A C D F GA GB H J L B B A MM NN Bore Size W 025 037 050 075 125 025
case) Operating environment No corrosive gas Enclosure IP67 Weight 120 g EX9-OET1, EX9-OET2, EX9-OEP1, EX9-OEP2 (Output block) Specifications Item EX9-OET1, EX9-OET2 EX9-OEP1, EX9-OEP2 Number of outputs 2 outputs Rated voltage 24 VDC Max. 62 mA (1.5 W) / point (When EX126, EX250 or EX260 is used) Rated load current Max. 0.5 A (12 W) / point 2 Max. 42 mA (1.0 W) / point (When EX500-Q 02 or
T2 M W Joint Joint/Mounting Bracket (Type A/B)/Part No.
200 to 240 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N() W M N() W W P3 P1 PE PE P4 P2 CNP2 CNP2 P(+) P(+) Regeneration option Regeneration option C C D D Encoder Encoder CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 240 VAC, power supply should be connected to L1 and L3 terminals, with nothing connected to L2.
Type A mounting bracket YA-03 Joint YU-03 RS T2 V M W Joint Joint/Mounting Bracket (Type A/B)/Part No.