Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: B (Brass or BC6, Copper Body & Shading Coil, EPR Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: B (Brass or BC6, Copper Body & Shading Coil, EPR Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: L (Stainless Steel Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: L (Light)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: H (Stainless Steel Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Bracket: B (Bracket)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: G (Stainless Steel Body & Shading Coil, NBR Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: J (Stainless Steel Body & Shading & Coil, EPR Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: J (Stainless Steel Body & Shading & Coil, EPR Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: F (G), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: A (Brass, Copper or BC6 Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)
Examples of Internal Circuit and Wiring 1 to 5 V / 4 to 20 mA output type With temperature sensor 1 to 5 V output type PF3W5--1/2 PF3W5--1T Analogue output 1 to 5 V Analogue output 1 to 5 V Output impedance: 1 k Output impedance: 1 k Analogue output 4 to 20 mA Maximum load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 -22No.PF-OMN0010-J Flow Measurement Measurement
_ _ 1 A 346 _ _ 0 B 818 _ _ 1 B 333 _ _ 0 C 750 _ _ 1 C 321 _ _ 0 D 692 _ _ 1 D 310 _ _ 0 E 642 _ _ 1 E 300 _ _ 0 F 600 _ _ 1 F 290 7 7 7.
Construction/Parts/Dimensions AN500 to 900 End plate (Carbon steel) Tension bolt (Carbon steel) (mm) Dimensions Sound absorbing material (Resin sintered body) Model Port size R, NPT AN500-06 AN600-10 AN700-12 AN800-14 AN900-20 A B D A Cover (Carbon steel) 3/4 107 46 36 Body (Aluminum alloy) 1 127 50 41 1 1/4 186 74 50 Hexagonal flats D 1 1/2 217 74 55 2 256 86 65 Port size B 4 Series AN Specific
no condensation) Polyurethane Shore D 57 Note 1) Consult SMC regarding other fluids.