IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, DIRECT OPERATED 2 PORT VALVE (N.O.), 2 PORT VALVE, K40, 400 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, DIRECT OPERATED 2 PORT VALVE (N.C.), 2 PORT VALVE, 400 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, DIRECT OPERATED 2 PORT VALVE (N.O.), 2 PORT VALVE, 400 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, K40, 400 lb
IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material:áaluminum,áresin, 2 PORT VALVE, 2 PORT VALVE, K40, 400 lb
C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 230 VAC (50/60 Hz)2.1 A5 A180/200 W 50/60 Hz220 W0.01 ?
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Long stroke option: up to 3000 mm (XB11); Auto switch capable
Bore sizes: 16, 20, 50, 63, 80, 100 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.10 ~ 0.15 MPa (15 ~ 22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Auto switch capable
Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Long stroke option: up to 3000 mm (XB11); Auto switch capable
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 5000 mm (XB11), up to 3000 mm for 16 bore; Auto switch
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.10 ~ 0.15 MPa (15 ~ 22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 5000 mm (XB11), up to 3000 mm for 16 bore; Auto switch
Bore sizes: 16, 25, 40 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000 mm; Minimum operating pressure: 0.10 ~ 0.15 MPa (15 ~ 22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 5000 mm (XB11), up to 3000 mm for 16 bore; Auto switch capable
Bore sizes: 16, 20 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Minimum operating pressure: 0.15 MPa (22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 1000 mm (XB11); Auto switch capable
Bore sizes: 16, 25, 40 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Minimum operating pressure: 0.10 ~ 0.15 MPa (15 ~ 22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 1500 mm (XB11), up to 1000 mm for 16 bore; Auto switch capable
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000 mm; Minimum operating pressure: 0.10 ~ 0.15 MPa (15 ~ 22 psi); Speed: 100~1000 mm/sec (w/o stroke adjustment bolt), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 3000 mm (XB11); Auto switch capable
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications
Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3M is compatible with secondary battery applications
LECSN-T drives an AC Servo motor with a 22-bit absolute encoder. Real time tuning and vibration suppression control adapt to current conditions as equipment wears over time, leading to short settling times and reduced downtime. Synchronous motions is possible with the EtherCAT® version.
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)
Body size: 16, 25; Strokes: 50, 100, 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 385 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm; Encoder resolution: 17-bit (S motors), 22-bit (T motors), 20-bit (V motors)