1600 15000 14 900 17500 1800 17500 15 1000 20 2000 20 62 No.JXC-OMU0004-A 11. 11.1 [5m ] A B-1 2 A A-1 1 LE-CP-1 L B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 S B B-6 9 B A-6 8 3 14.2 2 1 8 14) B1 A1 17.7 6 5 2 1 18 B6 A6 16 15 L 11 30.7 11.2 [820m] A B-1 2 A A-1 1 LE-CP-1 L B B-2 6 B A-2 5 8 8m*
6-8 P . 5-6-12 P . 5-6-20 P . 5-6-41 P . 5-6-35 P . 5-6-48 P . 5-6-54 P . 5-6-32 P . 5-6-26 Effective area (mm2) Number of ports 1 2, 3 Poppet 2.5 2, 3 Poppet 19 2, 3 Poppet 7 3 Balanced poppet 10.8 5 Rubber spool 18 5 Metal spool 9.9 5 Metal spool 18 5 Rubber spool 6 3 Balanced poppet Function Dual pressure is available only on external pilot. 5-6-2 5-6-3 2 Series VM Transmitters Effective
Solenoid Specifications Power consumption W (Holding) Voltage fluctuation % Apparent power VA Inrush Holding W/o silencer W/ silencer Frequency Hz Temp. rise C (Rated voltage) Pilot exhaust noise dB Power supply Model AC 50 20 11 4.5 5 to 60 60 6 5 to 40 Air operated Rated value 10 104 83 VXF 2150 DC VXF 2160 AC 50 20 11 4.5 5 to 60 60 6 5 to 40 DC Rated value 10 105 85 VXF 2280 AC 50 40
5 5 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 0 1 2 3 4 5 6 8 9 10 11 13 7 12 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) 50 63 1000 1000 Recommended driving force Fn (N) Recommended driving force Fn (N) 500 400 500 300 300 200 200 Usable range 100 100 Usable range
Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.
GA 8 8 GB 5 5 H 5 5 MM 28 28 Bore size 11 11 10-0.022 0 12-0.027 0 With air cushion Air cushion type is not available for 21-/22-CJ2.
0.5 1 5 10 20 50 0.5 1 5 10 20 50 Load (kN) Load (kN) Bore size 80 B rod C rod 2000 6 4 8 3 7 5 1 5 2 4 8 3 7 6 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 1 5 10 20 50 Load (kN) Load (kN) Bore size 100 B rod C rod 4 8 8 3 3 7 7 5 4 5 2000 6 6 1 2 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 100 1 5 10 20 50 100 Load (kN) Load (kN) 28 Series CH2E/CH2F/CH2G/CH2H Technical Data 3 Relationship
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
/With Male Thread Adapter: Vacuum Inlet Lateral Pad form Bellows type with groove ZP3E-Y32BMl-AL14 ZP3E-Y40BMl-AL14 ZP3E-Y50BMl-AL14 M14 x 1 Width across flats 19 Width across flats 19 M14 x 1 M14 x 1 Width across flats 19 M5 x 0.8/ Effective thread depth 5 5 5 26.5 44.1 69.1 25 M5 x 0.8/ Effective thread depth 5 23 40.6 65.6 25 5 5 M5 x 0.8/ Effective thread depth 5 21 38.6 63.6 25 5 5 M10
VQ 0 5 1 0 1 Y (Example) Manual override B C Flat cable with power supply terminal block and 3m cable VV5Q11-08C6G2 VQ1100-5 VQ1200-5 VQ1300-5 Series Non-locking push style Push-locking slotted style Push-locking lever style 1 set Manifold base No. 4 setsValve No. (Stations 1 to 4) 1 set Valve No. (Stations 5) 3 setsValve No.
18.5 21.6/14.9 3/16 6.3(1/4) KQL05-07 11.4 10 19.5 34.5 23.5 16.5 3.5 8 12 KQL08-12 15.2 12 23 40.5 26 18.5 21.6/14.9 3/16 8(5/16) KQL05-09 11.4 10 19.5 36.5 24 16.5 3.5 10 12 KQL10-12 18.5 17 26.5 42 30 21 35.2/25 1/4 8(5/16) KQL07-09 13.2 10 20.5 37.5 25.5 17 4.6 1/4 9.5(3/8) KQL07-11 13.2 10 20.5 39.5 25 17 4.6 5/16 9.5(3/8) KQL09-11 15.2 12 23.5 40.5 27.5 18.5 6 5/16 12.7(1/2) KQL09-
Prefix it to the part nos. of the solenoid valve, etc. 3 position pressure center (A) 4 (B) 2 1 (P) 3 (R) Caution For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 5-11-6. 5-2-22 Series SYJA5000 4/5 Port Air Operated Valve Specifications Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 (0.4 x P+0.1) to 0.7 P: Operating pressure 0.1 to 0.7 0.15 to 0.7 2 position
display . 5-9 Current circulating fluid temperature [PV] . 5-10 Circulating fluid set temperature [SP] . 5-10 Circulating fluid discharge pressure [Press PV] . 5-11 Circulating fluid flow rate [Flow PV]. 5-11 Circulating fluid flow rate [DI PV]. 5-11 Operation mode [MODE] . 5-12 RUN/STOP display . 5-13 Run/stop operation . 5-13 5.4.2 Menu . 5-14 5.4.3 Status screen . 5-14 5.4.4 Information
Nil W 2-5-5 Base Mounted 6 Series VQ4000 Plug-in Type Conduit terminal 2 position single: VQ410 0 1 23.5 23.5 50 158 50 90 108 158 Indicator light 11(12.5) 11(12.5) 5 3 2(B) port 4(A) port 9 4 2 38 48 10.5 1 11 A B 38 24.6 48 4 2 A 13.5 13.5 30 45 2-5.6 Mounting hole 14 5 1 3 12 30 45 2-5.6 Mounting hole 5-Rc 1/4, 3/8 (5(R1), 3(R2) port Rc 1/4) Manual override Courtesy of Steven Engineering
Model A L D Applicable Fitting Size d KQP-04 16 32 6 4mm KQP-03 16 32 6 5/32 KQP-06 18 35 8 6mm KQP-07 18 35 8 1/4 KQP-08 20.5 39 10 8mm KQP-09 20.5 39 10 5/16 KQP-10 22 43 12 10mm KQP-11 22 43 12 3/8 Phillips /Ordinary Round Head Screw Gasket Series SY3000-23-4 (M2x21) SY3000-11-8 SY3000 M3x26 (Non Glare Nickel Plating) SY5000-11-2 SY5000 M4 x 31 (Non Glare Nickel Plating) SY7000-11-2 SY7000
08, 09, 10, 11 03, 04 200 400 06, 07 02 01, 23 300 50 03, 04 100 200 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
AD37 AD37N(5) AD48 AD48N(5) AD47 AD47N(5) AD48 AD48N(5) Float type auto-drain N.O.
MGPM, MGPL Common dimensions (mm) Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW 42 29 11 7.5 8 8.5 9 M4 x 0.7 10 12 13 15 M4 x 0.7 4.3 4.3 5.6 5.6 M5 x 0.8 6 8 10 12 58 64 83 93 8 8 9.5 9.5 13 8 8 10 10 M4 M4 M5 M5 4.5 4.5 5.5 5.5 8 5 5 6 6 13 15 18 21 18 26 30 36 42 13 15 18 21 18 22 24 30 12 16 20 25 10, 20, 30, 40, 50, 75, 100 125, 150
will display. . 5-8 Menu key . 5-9 Display and setting of date and time . 5-9 Operating condition display . 5-9 Current circulating fluid temperature [PV] . 5-10 Circulating fluid set temperature [SP] . 5-10 Circulating fluid discharge pressure [Press PV] . 5-11 Circulating fluid flow rate [Flow PV]. 5-11 Circulating fluid flow rate [DI PV]. 5-11 Independent pump operation [Pump] . 5-12 Operation