SMC Corporation of America
Elite Part Number Search
Search Results "11-CDJ2F10-60-M9NLS"

114 186 340 405 485 660 870 20 40 60 30 60 10 40 60 L1 16 40 L2 MHL2-16D2 MHL2-20D MHL2-20D1 MHL2-20D2 MHL2-25D 146 98 158 178 116 226 138 238 278 166 1010 1175 1645 1840 1850 80 40 80 100 50 60 20 40 60 MHL2-25D1 MHL2-25D2 MHL2-32D MHL2-32D1 MHL2-32D2 MHL2-40D MHL2-40D1 MHL2-40D2 25 198 216 150 198 242 298 336 220 318 402 2720 2935 3070 3985 4820 100 120 70 120 160 188 246 286 40 30 32 20

LD LH LS LT LX LZ MM N NA NB NC 20 to 800 18 13 26 10 16 12 8 41 5 8 30 5 7 25 121 5.5 40 55 M8 x 1.25 13 26 19 15 15.5 25 to 800 22 17 32 12 16 12 8 46 6 8 32 5.5 7 28 121 5.5 40 55 M10 x 1.25 13 28 19 15 19.5 32 to 800 24 22 38 16 19 12 8 53 8 9 40 7.5 7 30 133 6 45 60 M14 x 1.5 13 36 19 15 21 40 to 800 24 24 41 18 21 14 11 54 10 11 48 7.5 9 35 158 6 55 75 M16 x 1.5 19 44 24 21 21 (mm)

Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

DC Specification Power consumption (W) Note 1) Temperature rise (C) Note 2) Size Apparent power (VA) Note 1) 2) Temperature rise (C) Note 3) Size Size 1 Size 2 2.5 3 60 60 Size 1 Size 2 2.5 3 60 60 Note 1) Power consumption, Apparent power: The value at ambient temperature of 20C and when the rated voltage is applied.

(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 82 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 84 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 98 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 102 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22 11

70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26 F 10 13 13 16 16 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 G 5.5 7.5 7.5 8 11 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 H 13 20 20.5 22 29 I 12 15 18 23 J 6 6 8 8 10 K 11 8 10 15 16 L 57 66 70 80 92 P (Piping

70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26 F 10 13 13 16 16 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 G 5.5 7.5 7.5 8 11 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 H 13 20 20.5 22 29 I 12 15 18 23 J 6 6 8 8 10 K 11 8 10 15 16 L 57 66 70 80 92 P (Piping

. 47 11.1 . 47 11.2 . 47 11.3 . 48 (1) . 48 (2) () . 48 (3) . 48 11.4 . 49 11.5 . 49 12() . 50 12.1 . 50 12.2 . 51 13 . 52 13.1 . 52 13.2 No. . 52 (1) . 52 [2] . 53 [3] . 54 [4](HOLD) . 54 [5] . 55 [6] . 55 (7) . 56 13.3 . 57 14. 58 14.1 [5m ] . 58 14.2 [820m] . 58 14.3 ()[5m ] . 59 15.4 ()[820m] . 59 14.5 . 60 14.6 . 60 14.7 . 60 -2- 14.8 . 61 15 . 62 15.1 IO . 62 15.2

Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 70 x 4.186 x 103 x 4.0 60 = = qm x C x (T2 T1) 860 Q = = 19535 [J/s] 19535 [W] = 19.5 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 19.5 [kW] x 1.2 = 23.4 [kW] 1 x 70 x 60 x 1.0 x 103 x 4.0 860 = Thermo-chiller T1: Outlet temperature Q: Heat generation amount 1680 [cal/h] 860 Users equipment = T = T2 T1

p. 9 Dimensions: 20 p. 11 Dimensions: 30, 40, 60 p. 13 Dimensions: 80 p. 14 Specific Product Precautions p. 15 3 ZNC Series Model Selection Selection Procedure [Basic type] Step 1 Calculate the lifting force.

My = 0.5 x 9.8 (10 + 11)/1000 = 0.11 A3 = 11 May = 1 x 1 x 9.14 = 9.14 Mymax = 9.14 K = 1 = 1 2 = 0.11/9.14 = 0.012 Examine Mr.

Home position return (PLC) 60 8.1 Returning to home position . 60 9. Positioning operation (PLC) 62 9.1 Setting of Operation data . 62 9.2 Movement MOD . 66 10.

Hz) Three phase 200 to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Main power supply Three phase 170 to 253 VAC Single phase 170 to 253 VAC Allowable voltage fluctuation [V] Single phase 85 to 132 VAC Rated current [A] 0.9 3.0 5.0 1.5 2.6 Single phase 100 to 120 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Control power supply voltage [V] Control

-11 3/8" 15.5 26.7 37 28.2 15.6 37 (38) AS42l1FSl-U04-11 3/8" 1/2 24 (23.8) 15.5 18.8 27.4 40.3 (40.2) 36.2 64.1 62.5 57 55.4 15.6 26 29 10 19 60 (59) AS42l1FSl-U04-13 1/2" 19.3 30.9 43.8 (43.7) 34.7 17 62 (61) 20.9 30 (30.3) 22.6 49.7 48.3 44.2 42.8 13.3 21.5 24 7.8 16.2 1/4 17 (17.5) 13 Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The values

7 M18 x 1.5 M8 x 1.25 depth 16 Up to 300 32 20 27 32 2 35 30 18 58 14 72 14 11 7 M18 x 1.5 M10 x 1.5 depth 16 Up to 300 38 20 27 32 2 35 32 18 71 20 89 20 13 10 M22 x 1.5 M10 x 1.5 depth 22 Up to 300 50 25 32 37 3 40 40 22 71 20 110 20 16 10 M26 x 1.5 M12 x 1.75 depth 22 Up to 300 60 41 30 37 3 40 50 26 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 NA P S TA TB ZZ 11 11

7 M18 x 1.5 M8 x 1.25 depth 16 Up to 300 32 27 20 32 2 35 30 18 58 14 72 14 11 7 M18 x 1.5 M10 x 1.5 depth 16 Up to 300 38 27 20 32 2 35 32 18 71 20 89 20 13 10 M22 x 1.5 M10 x 1.5 depth 22 Up to 300 50 32 25 37 3 40 40 22 71 20 110 20 16 10 M26 x 1.5 M12 x 1.75 depth 22 Up to 300 60 41 30 37 3 40 50 26 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 NA P S TA TB ZZ 11 11

VX3 Rated voltage 1 2 3 4 5 6 7 8 9 Valve/Body 0 Normally cosed/Single unit 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) VXA VN Solenoid valve option Nil Standard LVC Select an option mark in page 17-3-11 by Applicable Fluids Check List for special fluids outside of the standard.

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.