A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.
end nut CU CX +0.4 +0.2 L1 A + Stroke CL + Stroke B + Stroke L CW RR CZ 0.1 0.3 Rod end male thread Double Clevis (mm) A 42.5 B 8 CD 64 CL 4 CT 9 CU 8 CW CX 15 CZ 8 L 16 L1 6.5 RR 24.5 Size Stroke range 20 25 32 40 72 5 to 50 5 to 50 74 42.5 8 66 4 11 17 9 18 6.5 24.5 8 5 to 100 88 49.5 10 78 7 13 22 11 22 6.5 32.5 10 5 to 100 93 49.5 10 83 10 13 27 13 26 6.5 32.5 10 Double clevis bracket
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
D 4 4 6 6 E 60 90 90 90 F 30 60 60 60 G (50) (50) 100 100 Model LXFH5BC-25 LXFH5BC-50 LXFH5BC-75 LXFH5BC-100 Positioning Time Guide (for Horizontal Mount) For transfer load of 0kg For transfer load of 2kg Positioning time (sec) Positioning time (sec) Positioning distance (mm) Positioning distance (mm) 100 50 10 1 100 50 10 1 10 10 10.1 5.1 1.1 0.2 10.1 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s
For analog voltage output of 0 to 10 V Can be changed Can be changed 10 5 At the time of shipment At the time of shipment Analog output [V] Analog output [V] 1 0 105 10 0 105 10 10% of the rated flow range 1 100 1 100 10% of the rated flow range 100% of the rated Max. value of 100% of the rated flow range Max. value of the display range flow range the display range Flow [L/min] Flow [L/min
Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension
field resistant auto switch 50 A Y 100 P79WSE CKP1 Clevis width Number of auto switches A B 16.5 mm 19.5 mm Thread type Nil 2 pcs. 1 pc. n pcs.
(Different surfaces, Same surface), With 1 pc. 100 95 90 10 D-Y69 D-Y7PV D-Y7WV 100 + 30(n 4) 2 95 + 30(n 4) 2 90 + 30(n 4) 2 10 + 30(n 2) 2 (n = 4, 8, 12, 16) With n pcs. (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 2, 4, 6, 8) With 2 pcs.
MTS12-100 st 100 st 75 st 75 st 0.1 50 st 25 st 50 st 25 st 0 50 100 5 10 Lateral load (N) Lateral load (N) 40 16 0.3 0.3 MTS40-200 st 175 st 150 st 0.2 0.2 125 st 100 st 75 st 75 st MTS16-100 st 50 st 0.1 0.1 50 st 25 st 25 st 0 50 100 150 10 Lateral load (N) Lateral load (N) 20 0.5 Caution on Design MTS20-200 st 175 st 150 st Caution 1.
The INPoutput signal is turned on from 100[mm] 1[mm]=99 [mm] Area 2[mm] j Area 1[mm] j 100 b Speed[mm/s] 0 ON AREA Output signal OFF (INPOutput condition) INP Output signal ON In posn[mm] k OFF 101 99 0 10 20 30 40 50 60 70 80 90 100 Stroke [mm] -23- Example of step data input (2) < Positioning operation Relative > a b c d e f g h i j k No.
20m * Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (14.2) (2) 1 2 (5.5) (14) (1) B1 A1 5 6 (17.7) (3) 2 1 (18) A6 B6 (6.3) 15 16 (11) (30.7) -58- 14.3 ()[5m ] (1) (2) LE CP B A B-1 2 A A-1 1 (L) B (B-2) 6 B (A-2) 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (3) 5 5m Shield Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 B (B-6) 9 B (A-6) 8 3 (4) S 4 (+) B-
Port A size Port B size Number of Port A Porting Port A Port B Model 4 8 10 12 Rc(PT) Rc(PT) 6 8 10 6, R(PT) 6, R(PT) 6, R(PT) 8 ,R(PT) 8, R(PT) 8, R(PT) 10, R(PT) 10, R(PT) 10, R(PT) 6 8 10 4 6 6 8 One-touch fitting One-touch fitting 6, 10 KM11 1 4 3 8 Rc(PT)female thread 6, 10 One-touch fitting KM12 One-touch fitting One-touch fitting 3 KM13 1 8 1 4 3 8 1 8 1 4 3 8 KM11 One-touch fitting
HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
10 ISO Class 8 10 10 0 L/min (ANR) ISO Class 7 ISO Class 7 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] ISO Class 6 ISO Class 6 10 10 0 L/min (ANR) 50 L/min (ANR) ISO Class 5 ISO Class 5 10 10 1000 1000 20 L/min (ANR) ISO Class 4 ISO Class 4 100 100 70 L/min (ANR) 30 L/min (ANR) 10 10 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particle diameter
40 32 MLGP 30 40 50 30 40 50 25 40 RLQ Load weight: m (kg) Load weight: m (kg) 20 32 20 20 [Example] 25 MLU 10 10 20 ML1C 5 4 5 4 3 D3 2 2 -X 1 1 200.5 0.5 100 500 400 300 200 100 500 400 300 200 1000 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 200 200 40 100 100 32 30 40 50 30 40 50 40 25 20 32 Load weight: m (kg) Load weight: m (kg
ANR)] 200 100 400 300 600 500 700 0 Time to Reach Vacuum (Representative value) ZL1 Series ZL3/ZL6 Series ZL3m ZL6m (Tank capacity: 1 L) (Tank capacity: 1 L) 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Vacuum pressure in tank [kPa] Vacuum pressure in tank [kPa] ZL6H ZL6M ZL3H ZL3M Time to reach vacuum [S] 1 2 3 4 5 6 0 Time to reach vacuum [S] 1 2 3 4 5 6 7 8 9 10 0
Detecting port Installation Detection range distance mm mm 10 45 25 100 50 180 M3 screw Unit: mm A B 10 20 20 40 25 45 30 55 40 65 50 75
pressure center 2 (B) (A) 4 Symbol 3 6 10 15 20 30 100 Lead wire length Note 5 Note 1) 300 mm (EA) 5 1 (P) 3 (EB) 600 mm Maximum length for L-type 1000 mm 4-position dual 3 port valves (N.C.
The rotation angle can be adjusted between 0 to 100. The rotation angle can be adjusted between 0 to 100. Symbol -XC12 to XC21 CRB2 CRBU2 L L B B 10 CRB1 End of rotation Rotation starting point 10 Additional Reminders MSU A The rotation starting point is the position of the flat and the key groove when the actuator is pressurized through connection port B.
Purchasing order is available in units of 10 pieces. (0.35 W) p Nil Standard p p (0.9 W) B Note) High speed response type High pressure type (Metal seal type only) (0.9 W) p K Note) Note) Option Electrical entry Coil voltage Light/surge voltage suppressor 1 2 3 4 5 6 Electrical entry Symbol 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Y YO YZ