Add to Cart SMC EX600-ZMV2 valve plate, EX300 SERIAL INTERFACE UNIT $15.85 + Add to Quote Add To Cart Add to Cart SMC KQ2P-08
Add to Cart SMC EX600-ZMV2 valve plate, EX300 SERIAL INTERFACE UNIT $15.85 + Add to Quote Add To Cart Add to Cart SMC KQ2P-08
SMC VVQ1000-50A-C6 fitting assy, VV5Q* MANIFOLD VQ 4/5 PORT (sold in packages of 10; price is per piece)*** $3.47 + Add to Quote Add To Cart Add to Cart SMC VVQC1000-TR-08
SMC VVQ1000-50A-N7 1/4 fitting, VV5Q* MANIFOLD VQ 4/5 PORT (sold in packages of 10; price is per piece)*** $3.47 + Add to Quote Add To Cart Add to Cart SMC VVQC1000-TR-08
The use of 34 pin connectors allows up to 16 stations with double solenoids.Plug-in connector connecting base , Side ported , Available with external pilot , One-touch fittings , Applicable Fieldbus protocols: DeviceNetÖ, PROFIBUS DP, CC-Link, EtheNet/IPÖ, EtherCAT, SS5V 08 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID VALVE, VVM, 0.96 lb
Stations: 08 (8 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port
.: 08 (ø8), Port Size/Applicable Tubing O.D.: 02 (R1/4, Rc1/4), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)
.: 08 (ø8), Residual Pressure Release Function: without Residual Pressure, Thread Type: G (G), Size: 02 (1/4)
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa FUY-08 KQ2 FITTING. FITTING, UNION Y. CONNECTORS. KQ2 1/2. 0.0748 lb. MR.
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa FUT-08 KQ2 FITTING. FITTING, UNION TEE. CONNECTORS. KQ2 1/2. .03719 lb. MH.
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa FSU-08 KQ2 FITTING. FITTING, STR UNION. CONNECTORS. KQ2 1/2. .01902 lb. MD.
Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 01 (1/8), Applicable Tubing O.D: 08 (ø8), Sealant: S (w/Sealant)
"SS5V 08 Station Manifold. 4/5 PORT SOLENOID VALVE. N lb. SV.