The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
(NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12 V 12 V Diagnostic indication (2-color indication) Auto switches marked with are produced upon receipt of order.
MQR Symbol O.D. x I.D. 0425 4 x 2.5 0604 6 x 4 0805 8 x 5 1065 10 x 6.5 1208 12 x 8 Symbol Number of cores X169 2 cores X170 3 cores X171 4 cores X172 5 cores T T IDK Tube length per roll [m] Color*1 Symbol Length A 1 B 2 C 3 D 4 E 5 F 10 G 20 Symbol Color Symbol Color 1 Black 5 Yellow 2 White 6 Green 3 Red 7 Translucent*2 4 Blue 8 Yellow brown Yellow Blue Red White Black Inside of the roll
ALF400 to 600 1 1 2 2 1 Metal case with a level gauge X208 ALF400 to 900 2 1 4 3 1 1 1 2 4 1 Line pressure (MPa) 2 1 Note 1) Tank pressure is removed when line pressure is stopped.
Rc1/2 G1/2(3) Nil F N T 1/2-14 NPT 1/2-14 NPTF P Note 1) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October ,99.
Cover mounting area Cover How to Order N 04 DM 6 Number of connecting tubes Accessory (Option) 1 cover (Single side) 2 covers (Both sides) C1 C2 6 12 6 12 Style Tube material Nil P S Multi-connector Plug side Socket side N Nylon Soft nylon Polyurethane NU Tubing O.D. 4 mm 6 mm 04 06 15-2-101
wire 12 V 3-wire (NPN) Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit Relay PLC 24 V 3-wire (PNP) 2-wire Yes Grommet 12 V 3-wire (NPN) 5 V, 12 V 12 V Water resistant (2-color indicator) IC circuit M9PAV1 M9PA1 3-wire (PNP) 2-wire M9BAV1 M9BA1 A96V A96 5 V 3-wire (NPN) 100 V IC circuit 24 V Yes A93V 2 A90V A93 Grommet Relay PLC 2-wire 12 V A90 No IC circuit 100 V or less
Note 6) Fixed unit: Instantaneous ow: L/min, Accumulated ow: L Option 1 H Note 2) PNP External input Note 3) With lead wire and M8 connector (3 m) Note 4) Note 2) Made to Order Note 3) Can be selected from accumulated ow external reset and peak/bottom reset. Nil N Without lead wire and M8 connector Note 4) Each option is not assembled with the product, but shipped together.
Within 2%F.S. Within 0.75%F.S. Within 1%F.S. Within 0.5%F.S.
Number of step data (Points) I/O cable length [m] 2 2 stroke end points/ 12 intermediate points (Programless) Nil 1 3 5 Without cable 1.5 3 5 Parallel I/O type N P NPN PNP The controller is sold as single unit after the compatible actuator is set. Confirm that the combination of the controller and the actuator is correct.
Delay time setting can prevent the output from chattering. (5) Press the button for 2 seconds or longer to complete the OUT1 setting. : If the button is pressed for less than 2 seconds, the setting will be returned to P_1.
How to Order CP96S B W J 32 100 C CP96SD B W J S 32 100 M9BW C With auto switch With auto switch (Built-in magnet) Number of auto switches Mounting B Basic L Axial foot F Rod ange G Head ange C Single clevis D Double clevis Bore size Nil 2 S 1 3 3 n n 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm * Mounting brackets are shipped together, but not assembled.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + H Mounting Without mounting option With bracket With set nut a Nil B Note 4) + Without auto drain Float type auto drain (N.C.)
PNP open collector 1 output NPN open collector 2 outputs PNP open collector 2 outputs With digital pressure switch Fittings Nil L Straight Elbow Note 1) Two plug nuts are mounted on the gauge port.
Card Motor Series LAT3 RoHS How to Order 1 N 1 D LAT3 10 Sensor resolution Nil Controller mounting Nil 30 m DNote 3) Screw mounting F 1.25 m DIN rail mounting I/O cable lengthNote 2) Stroke Nil 10 20 30 Without cable 10 mm Note 1) Refer to page 3 for detailed specifications of the controller. Note 2) If Without controller has been selected, the I/O cable is also not included.
Rotary Table/Rack & Pinion Style Series MSQ Size: 1, 2, 3, 7 How to Order MSQA A M9BW 1 High precision type MSQB A M9BW 1 Basic type Number of auto switches Size Nil S n 2 pcs. 1 pc. n pcs. 1 2 3 7 Auto switch type Nil Without auto switch (built-in magnet) Refer to the table below for auto switch types. The auto switch is included in the package (unmounted).
class Thread tolerance With thread/Without thread Rod end thread Panel mounting Plug mounting Mounting method Mounting nut (2) Mounting nut (1) Standard accessories Hose nipple (1) Gasket (1) Rod end nut (2) Rod end nut (2) Provided to the model with rod end nut.
Nil S n 2 pcs. Bearing type 1 pc. M L Slide bearing n pcs. Ball bushing bearing Auto switch Without auto switch (with built-in magnet) Nil Refer to the below table for auto switch model numbers.
Compact Rotary Actuator Rack & Pinion Style Series CRQ2 How to Order CRQ2B S 20 90 Without auto switch CDRQ2B S 20 90 M9BW With auto switch Built-in magnet Number of auto switches Shaft type S W Single shaft Double shaft 2 pcs. 1 pc. n pcs. Nil S n Refer to pages 254 and 255 for the shaft type variations.