Base Mounted Wiring: Base Mounted Plug-in w/Multi-connector on U Side, Stations: 03 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 1/2, Thread: NPTF, Exhaust Cleaner Mounting Direction: -
Stations: 03, System, Port Combinations: Ejector System, Common PV: ø5/16", Inch Size, Exhaust: 1 [Ejector System, Silencer Common Exhaust (End Plate on Both Sides)], Wiring: D-sub Connector, 25 Pins, Option: -, Manifold Assembly, Delivery Condition: -
Body Size: IR3000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 1 [0.005~0.4MPa (IR1000/2000) or 0.01~0.4MPa (IR3000)], Thread: NPT, Port Size: 03 [3/8 (IR3000 Only)], Accessory: -, Temperature Environments: -, Suffix: -, Made to Order: -
Valve Stations: 03, SUP/EXH Block Fitting Entry Direction: 1 (Standard, Same Direction as the Cylinder Ports), SUP/EXH Block Port Size: N7 (ø1/4" One-touch Fitting, Straight), Mounting Option: F2 (w/Bracket, Port Downward)
Size: 30, Base Dew Point: H (-15°C), Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: N (NPT), Port Size: 03 (3/8), Draining: J (Drain Guide Port 1/4 w/o Valve)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 03 (ø5/32)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 03 (ø5/32)
Body Class: 1 (Orifice Dia. ø2), Valve Type: 0 (N.C.), Applicable Tubing Size: 03 (ø3mm or 1/8"), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 1 (With Flow Rate Adjustment)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet Lead Wire 0.6m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: B (Locking Slotted Style), Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8), Thread: T (NPTF)
Speed controller with Model Port size 4 6 8 10 12 ASD One-touch fittings for AS121-M5 AS221-01 AS221-02 AS321-02 AS321-03 M5 x 0.8 AS 1 8 R metal body specifications 1 4 R AS-FE 1 4 Usesflameresistantresinasstandard. (ULstandardV-0) R 3 8 R KE AS421-04 1 2 R Note 1) :Brasspartsareelectrolessnickelplated,providedasstandard.
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: B (Bottom Ported), Port Size: 03 (3/8)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 4 (220VAC 50/60HZ), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8)