In the actual setting, adjust them after confirming the auto switch operating condition. 30 - Maintenance and Inspection For most suitable use of rotary table, regular inspection is required according to the operating condition.

MRQB32,40 18 1 17 2 16 2 34 2 15 1 33 O 1 14 1 32 4 13 2 31 2 12 O 1 30 1 11 2 29 1 10 1 28 S 1 9 1 27 S 1 8 O 2 26 1 7 1 25 2 6 1 24 4 5 1 23 4 4 1 22 4 3 1 21 O 3 2 1 20 O 1 1 1 19 1 12 14 2 28 1 13 2 27 1 12 4 26 1 11 1 25 R 1 10 1 32 24 2 9 2 23 2 8 4 22 8 7 1 21 2 6 2 20 2 5 1 19 2 4 1 18 O 4 3 1 17 O 4 2 1 16 4 1 1 15

Wiring example to robot controller (common to NPN/PNP) . 30 5-4.YASKAWA Plug & Play Kit . 31 5-4-1. Installing YASKAWA Plug & Play Kit . 31 5-4-2. Tool Presets . 36 5-4-3. Utility Window . 37 5-4-4. Air Gripper Integration Window . 38 5-5. Air supply . 42 5-6. Piping . 43 5-7. Operating environment . 43 5-8.

Low frequency operation The valve should be switched at least once every 30 days to prevent malfunction. The product requires periodic inspection every 6 month for optimum operating conditions. 3. Disassembly Do not disassemble the product except the replacement of the diaphragm assembly. Caution 1.

Drain flushing Rc1/2 28 to 30 Follow the procedure of the manufacturer when fittings If condensation in the drain bowl is not emptied on a other than SMC is used. regular basis, the bowl will overflow and allow the condensation to enter the compressed air lines. It causes Wiring malufunction of pneumatic equipment.

If excessive carbon dust is generated by the compressor, it may adhere to the inside of a valve and cause it to malfunction. (3) Low-frequency operation Valves should be operated at least once every 30 days to prevent malfunction.

Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. When instructions are given in the Specific Product Precautions, follow these specifications. Lubrication 1. Lubrication [Rubber seal] 1) These valves can be used without lubrication. 2) If a lubricant is used in the system, use class 1 turbine oil (no additive), ISO VG32.

Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. 1.

Low frequency operation Switch valves at least once every 30 days to prevent malfunction. Also conduct a regular inspection once every 6 months, in order to use it under the optimum conditions. 1. Filters and strainers 1. Be careful with clogging of filters and strainers. 2. Replace filter elements after a year of use, or earlier if the pressure drop reaches 0.1 MPa. 3.

Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.

Val: 1 to 65000 4 Valve ON/OFF counter (Counter) 8 Disable Does not generate an error. 1: This function is valid only when Hold/Clear priority of the system parameter is set to Handheld. 2: Some PLC does not support an idle mode. 3: The count is memorized every 30 seconds per channel.

M3 x 30 screw for connection to the valve manifold. Seal cap 1 pc. seal cap for unused fieldbus interface connector (BUS OUT). 1: Refer to page 28 for applicable connector cables. 2: Refer to page 16 for the LED Indication and Settings. -9No.EX-OMP0005-I Installation and Wiring Installation Connect valve manifold to the SI unit.

Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.

Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.

Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.

Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. When instructions are given in the Specific Product Precautions, follow these specifications. 4. Closed center types For closed center type, check the piping to prevent air leakage from the piping between the valve and the cylinder. 5.

Inclination from the vertical line should be less than 5. 3) Install one-touch fitting (width across flats: 17) to drain port (width across flats: 30) and the drain tube. 4) Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer unit. Insert the drip-proof connector to the deepest part.

Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.

ZB-OM00201-B Contents Safety Instructions 2 Model Indication and How to Order 10 Names of parts of product 16 Mounting and Installation 18 Air Supply 20 Supply Pressure 21 Piping 21 Handling of the V Port Assembly 22 Solenoid Valve 26 Construction 30 Maintenance 31 Replacement Procedure for Filter Element 36 Replacement Procedure for Silencer 37 Replacement Procedure for Solenoid Valve (Supply

EX120/121/122/124U/124D-SCS1 EX120/121/122/124U/124D-SCS2 Applicable system CompoBus/S Communication specifications Node address setting range 0 to 14 0 to 15 Communication speed 750 kbps Cable length Cable type Main cable length Branch cable length Total branch cable length When using VCTF cables 100 m or less 3 m or less 50 m or less When using special flat ribbon cable 30 m or less 3