SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-A-46-AS"

Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, ELBOW, AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), .14109 lb

Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, ELBOW, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .42768 lb

Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL 1/4 PT, AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), .31020 lb

Using SMC speed controls with built in one-touch fittings minimizes installation time, reduces mounting height and enables a more compact machine design. These speed controls allow the body to be rotated to facilitate simple installation.

The AS*002F speed control series is RoHS compliant.Accessory: bracket for AS*002F, KIT, L-BRACKET, AS4002F, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, 22, AS***F NO SIZE KIT/ACCESSORY, .06556 lb

The series is offered in sizes ranging from 1/8 to 1/2 metric R(PT).Speed controller with residual pressure release valve, Body sizes: 1/8, 1/4, 3/8, 1/2, Port sizes: /8, 1/4, 3/8, 1/2, SPEED CONTROL W/EXHAUST VALVE, AIRLINE EQUIPMENT, AS FLOW CONTROL, EB, AS 3/8INCH STANDARD (PT), .29169 lb

The series is offered in sizes ranging from 1/8 to 1/2 metric R(PT).Speed controller with residual pressure release valve, Body sizes: 1/8, 1/4, 3/8, 1/2, Port sizes: /8, 1/4, 3/8, 1/2, SPEED CONTROL W/EXHAUST VALVE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .48863 lb

The silencer part number for the VQZ200 and VQZ2000 series is “INA-25-46.”
When mounting with a (ø6) One-touch fitting, it will be “IN-457-32L.”
Please refer to the following documents.
In addition, the AN120-M5 BC sintered body type silencer is dimensionally interchangeable with the AN05-M5.

Cushion seal Urethane Since the lock of the CNA2 series cannot be disassembled and is normally replaced as a unit, kits are for the cylinder section only. These can be ordered using the order number for each bore size. Seal kit includes a grease pack (40 and 50: 10 g, 63 and 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.

Cushion seal Urethane Since the lock of the CNA2 series cannot be disassembled and is normally replaced as a unit, kits are for the cylinder section only. These can be ordered using the order number for each bore size. Seal kit includes a grease pack (40 and 50: 10 g, 63 and 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.

Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: w/o Plug, Input, Output Specification: P (PNP), Power Supply Cable Length: 5 (5m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller &
High-voltage Power Supply: U (Controller

Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: w/o Plug, Input, Output Specification: P (PNP), Power Supply Cable Length: 3 (3m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller &
High-voltage Power Supply: U (Controller

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)],

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: Y (w/o

. · The amount of space required for maintenance has been reduced (reduction of up to 46%). · Improved visibility and safety The bowl is completely covered by transparent bowl guard. This allows for 360° monitoring while also protecting the bowl from the external environment, helping improve safety.

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation

The CRB1 series clean room specification is still available (as of 2021).
However, there is no clean room specification for the CRB2-Z and CRB series.
The 10-CRB1 and 21-CRB1 series catalog can be found <a href="/webcatalog/en-jp/seriesList/?type=GUIDE&id=CRB1-E" target="_blank">herea>.