Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G), Bracket: None, CE-Compliant: Q (CE-Compliant)
Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Bore Size: 20mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 10 (1), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: Â
m, AFM: 0.3 ?m (99.9% filtered particle size)Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) Note 4) Note 5)200PolycarbonateSemi-standardRelieving type0.74
m, AFM: 0.3 ?m (99.9% filtered particle size)Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) Note 4) Note 5)200PolycarbonateSemi-standardRelieving type0.74
m, AFM: 0.3 ?m (99.9% filtered particle size)Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) Note 4) Note 5)1100PolycarbonateStandardRelieving type1.76
m, AFM: 0.3 ?m (99.9% filtered particle size)Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) Note 4) Note 5)1100PolycarbonateStandardRelieving type1.76
m, AFM: 0.3 ?m (99.9% filtered particle size)Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) Note 4) Note 5)1100PolycarbonateStandardRelieving type1.76