FMW-4300-2 .2 2 30 .1 .2 4A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about the product specifications and outline dimensions. 7 Green 8 Yellow CH4_OUT1 Auto shift input DOWN button UP button 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown CH3_OUT1 CH2_OUT1 CH1_OUT2 CH1_OUT1 DC(-) DC(+) URL http://www.smcworld.com SET button Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku

The screws should be further tightened 1/4 to 1/2 turns after assembly. 4, Setting of response time Set response time of switch output. Output chattering is prevented by setting the response time. Press the or button to select response time.

turn lever knob 6) Pull twist knob 8) Multi turn round knob (1 1/2 turn) Knob Option (Part number: AP PL227) 9) Operational Safety Device (OSD) N/A N/A Standard Option (Part number: AP PL225) 9) LOTO (Lockout) 6) Optional lever color available.

(B) 2 VP4 Metal 4 VQ 1/2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 2 Porting specications 2-position double 3-position pressure center (A) 4 (B) 2 Rubber (A) 4 (B) 2 VQ 4/5 Nil Side ported B Bottom ported 5 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQC 1/2 Manual override 3-position double check (A) 4 (B) 2 Note) 6 VQC 4/5 VQC 4/5 B: Locking type (Tool required) C: Locking type (Manual) Nil:

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines .

(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.

Linearity 1% FS Hysteresis 0.5% FS Repeatability 0.5% FS Monitor Output 1~5VDC analog transistor (NPN, PNP), max. 30mA 1Except ITV201, which is 29PSI.

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A

Operation Manual/VBAT-M36 Operation Manual/VBAT-M36C Operation Manual (Japanese) Operation Manual (Chinese) 1 copy 1 copy Anchor bolt, nut For VBA2 / 4 mounting 4 pcs. Hex. socket head bolt For VBA2 / 4 mounting 4 pcs. O-ring For VBA2 / 4 mounting 1 pc. Accessory set VBAT20A-Y-3 Hex. socket head plug For Drain port 1 pc. 1 pc. 1 pc. 1 pc. Product certificate Certificate 1 pc.

Operation Manual/VBAT-M47 Operation Manual/VBAT-M47C Operation Manual (Japanese) Operation Manual (Chinese) 1 copy 1 copy Anchor bolt, nut For VBA2 / 4 mounting 4 pcs. Hex. socket head bolt For VBA2 / 4 mounting 4 pcs. O-ring For VBA2 / 4 mounting 1 pc. Accessory set VBAT20S-Y-4 Hex. socket head plug For Drain port 1 pc. 1 pc. 1 pc. 1 pc. Product certificate Certificate 1 pc.

Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.

Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.

optional) 2-Rc 1/4 ATM port, OUT port 4-M x 0.8 thread depth 6mm through Mounting hole OUT 2 G 15 19 R3.5 25 7 36 (10) 30 L-bracket INI-398-0-6 (optional) 2-Rc 1/4 ATM port, OUT port (7) 36 3

VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.

4 1 2 3 4 Symbol Nil Type Rc Single phase 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID Series Working Principle Flow Rate Inlet pressure: 0.7 MPa Pressure drop (MPa) HAA HAW The compressed air that flowed in from the IN side passes through the