Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
RoHS MadetoOrder HowtoOrder 2F 12 400 AS Lubricant:Vaseline -X12 Ex.)AS2002F-04-X12 ApplicabletubeO.D.
Brown DC (+) OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 GND VCC NC OUT 6 L side R side Load Black OUT Main circuit + 12 to 24V DC MAX.80mA PSE Blue DC () ZSE4 ISE4 ZSE5 ISE5 PNP Open Collector (Sourcing) ZSE6 ISE6 Brown DC (+) q w e r t y ZSE3 ISE3 Main circuit 12 to 24V DC MAX.80mA + Black OUT GS Load Blue DC () PS ISA Precautions ZSE1 ISE1 Be sure to read before handling.
to 20 , 1 4 3 175 250 135 209 460 613 175 250 2 1 1 1 4 1 2 , , ALDU600-06 to 10, ALDU900-12 to 20 D.P.
Port size A B C D E F 28 3/4 31 34 22 143 107 IF320 104 1 37 62 89 28 194 IF321 IF323 104 1 29 39 56 28 161 16-12-9 5 Series IF3 Flow Rate vs.
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
Proper tightening torque Nm Tightening torque for piping (ftlb) Connection threads M5 1.5 to 2 (1.11 to 1.48) Rc 1/8 7 to 9 (5.16 to 6.64) Rc 1/4 12 to 14 (8.85 to 10.33) Rc 3/8 22 to 24 (16.23 to 17.70) Reference Tightening of M5 fitting threads After tightening by hand, tighten approximately 1/6 turn further with a tightening tool.
A B d H Model H A SN-015A M14 x 1 19 21.9 5 ZPNA-M16 M16 x 1.5 22 25.4 6 ZPNA-M18 M18 x 1.5 27 31.2 9 ZPNA-M22 M22 x 1.5 30 34.6 8 Bolts (Hexagonal Socket Head Cap Screw) Dimensions d B (mm) A B d L 8 11 5.5 M3 x 0.5 L 8 12 7 M4 x 0.7 A 10 15 8.5 M5 x 0.8 13-11-96
i 1 6 30 46 1 0 21 50 168 0 70 I 12 90 50 1 0 58 238 52 1 . 2 66 31 % 44.5 1 3 23 60 182 0 86 105 59 130 58 52 1 1 . 2 66 37 % 55 1 5 70 208 0 '102 1 8 130 160 71 297 65 't2.5 80 1 4 40 12 1 5 25 80 226 0 1 1 6 13.5 t 8 150 92 1 8 0 72 3 1 6 65 14.0 8 1 ra Single Glevis Type/CLAC with Bod Boot M14x r.5 M 1 8 X 1 . 5 M18X1.5 M22X1.5 M26X1.5 Dill|o||$io[$ $enies CIA Double Glevis TyPe/CLAD
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above table may be limited, depending on the hysteresis of an auto switch, etc. 12-12-15 12-12-16
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
AS120M-M5 M5 x 0.8 9 9 8 10 28.2 24.8 10.3 29.8 33.2 AS120M-U10/32 10-32 UNF AS220M-01 12 R 1/8 Rc 1/8 14.3 14.6 18 31.4 27.4 14.1 32.4 36.4 AS220M-N01 NPT 1/8 12.7 AS220M-02 17 R 1/4 Rc 1/4 18 19.5 27.2 35.9 29.9 18 34.9 39.9 AS220M-N02 NPT 1/4 17.5 Dimensions of R and NPT threads after installation. 15-9-63
Solenoid valve model VO307-1 0.3 to 0.7 MPa Valve unit Small flow Large flow Solenoid valve type Stop valve Skip valve Valve type Nominal size (mm) 63, 100 100, 160 External pilot pressure N.O No mark 100, 200, 110, 220, 240 No mark N.O AC (50/60 Hz) Coil rated voltage (V) 24, 12 Valve opens when solenoid valve conducts electricity.
Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.
S Without bracket (Bottom view) Model Port size A B C D E F G H I J K L M N O P Q R S T U LFE1l3l 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 LFE1l4l 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 LFE2l 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 62 53 4.6 9.5 14 56 38 2.5 depth 8.5 2.6 LFE3l 1 120 90 55 32 73 100 106