SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-N01-WY"

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

L/A OUT L/A IN Connector (BUS OUT) Connector for fieldbus outputs. 3 4 Marker groove Groove for an identification marker. 5 Connector (PCI) Connector for Handheld Terminal. (1) (2) (3) 6 MAC address label Displays the 12 digit MAC address which is different for each SI unit. LED display Content The power supply for control and input is OFF.

Connector pin assignment 6 Configuration 9 10 7 Pin number Signal name L/A PORT2 L/A PORT1 PORT1 PORT2 8 TX+ 1 1 2 1 2 No. Description Function 2 RX+ To obtain more detailed information about operating this product, please refer to the SMC website (URL https://www.smcworld.com) or contact SMC directly.

L/A IN 1 Status display LED Displays the status of the unit. L/A OUT L/A IN 2 Display cover Open to access the setting switches. (3)When mark B has been turned 180 degrees (1/2 turn), wiring is complete. Confirm that the connection is not loose. If turned too far, it will become difficult to remove the connector. Displays the communication status of the BUS OUT side physical layer.

L/A IN Displays the communication status of the BUS IN side. L/A OUT L/A IN Displays the communication status of the BUS OUT side. 2 Display cover The display cover should not be opened. (3)When mark B has been turned 180 degrees (1/2 turn), wiring is complete. Confirm that the connection is not loose. If turned too far, it will become difficult to remove the connector.

L/A PORT2 L/A PORT1 Installation If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.

s (Viscous flow) 20 Shows flow rate when P=0.1MPa 18 16 XLGR-80*-1* 14 12 10 8 6 4 2 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Adjusting screw rotations n 8 XL-OMP0001 4.

Main Body (1) Air servo cylinder IN-777 160 L H F J 300 TF S Made to order Bore size 125 125 mm Auto start function 160 160 mm Nil Without Auto start function 200 200 mm S With Auto start function 250 250 mm LED alarm display 320 320 mm L With LED alarm display Port thread type Communication protocol TF G H 4-20mA/HART communication Rod boot J Silicone rubber material A Nylon tarpaulin Stroke

Option 1 Piping specification Nil No option 02 Rc1/4 S Lead wire (5 m) with M12 straight connector N02 NPT1/4 F02 G1/4 (ISO1179) L Lead wire (5 m) with M12 right angle connector Output specification Unit specification 27 2 settings NPN open collector 2 outputs Nil With unit conversion function 1 M Fixed SI unit 2 NPN open collector 1 output 43 1 setting + P Pressure unit: psi (initial value