Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNT (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, BA, VQZ100 BODY
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL 24VDC,
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BASE MT
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
The VQ20/30s long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110,
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, VALVE,
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, "CONNECTOR ASSY, 3 PORT
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNT (DC) *LQA, VALVE, VQZ100 VALVE, SOL 3-PORT, NA, VQZ100 BASE
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNT (DC), VALVE, VQZ1000 VALVE, SOL 4/5-PORT, 2D, VQZ1000
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure: 0.8MPa), Cv factor: 2 position metal seal 0.15; 2 position rubber seal 0.2 3 position metal seal 0.11; 3 position rubber seal 0.15, Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position 15 or less; 3 position 25 or less, Ambient and fluid temperature: -10 to
The VQ20/30s long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110,
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less