Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B
/4 PC5/16-N02 $0.63 1/8 NPT1/4 PC1/8-N02 $0.63 5/16 NPT3/8 PC5/16-N03 $0.93 5/32 10-32UNF PC5/32-U10 $0.63 3/8 NPT1/8 PC3/8-N01 $0.96 5/32 NPT1/8 PC5/32-N01 $0.63 3/8 NPT1/4 PC3/8-N02 $0.96 5/32 NPT1/4 PC5/32-N02 $0.63 3/8 NPT3/8 PC3/8-N03 $0.96 3/16 10-32UNF PC3/16-U10 $0.63 3/8 NPT1/2 PC3/8-N04 $1.41 3/16 NPT1/8 PC3/16-N01 $0.63 1/2 NPT1/4 PC1/2-N02 $1.41 3/16 NPT1/4 PC3/16-N02 $0.63 1/
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb
23 9.5 55.3 1.5 49.3 R 1/4 19 AS331F-02-10ST AS231F-N02-11ST 3/8" 17.9 20.2 18.5 21 32.6 54.4 10 43.7 38.7 31 47 16.2 23 AS331F-02-12ST AS331F-N02-07ST 17 1/4" 13.2 20.9 22 34.4 56.2 12 44.9 38.7 25.6 50 12.9 20.6 AS331F-03-06ST AS331F-N02-09ST NPT 1/4 19 55.3 5/16" 15.2 23 12.8 1.5 49.3 9.5 17 25.2 46.1 6 18.5 38.5 39.7 28.2 54.4 12.9 20.6 AS331F-03-08ST AS331F-N02-11ST 16.2 21 3/8" 17.9
C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 IN port size IN port size Construction The construction and materials are the same as the standard product. Refer to Construction on page 323. The symbol stands for unavailable combination. The symbol stands for unavailable combination.
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual