Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 3 (PF2W511: 10~100), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 3 (PF2W511: 10~100), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: PF2W511: 10~100, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2W511: 10~100, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit