used with air or water Can be used with air or water Bronze (CAC) VXB215C F 18 7.6 3/4 (20A) 0.4 0.6 1 2 Port Solenoid Valve Variations Series Direct Operated Compact VDW Series VX Series Air Air Medium vacuum Medium vacuum Water Water Oil Oil Steam Steam Air Air Medium vacuum Medium vacuum Water Water Can be used with heated water Can be used with heated water Single Unit Manifold (Air
Long continuous loading time When power will be applied continuously for extended periods of time, use type VKF33E. However, it cannot be used with high frequency. Contact SMC if it will be operated more than once a day. 3. Be sure to perform switching at least once every 30 days. 1.
back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented.
Hold/Release success: default output DO[101] Hold/Release failure: default output DO[102] * Digital output port can be selected within DO[101] to DO[112] * you select the same digital output port for different status signals, a warning message will be displayed. 2. Test run The manual operation of the magnet gripper unit can be checked.
The stop and skip valves must be normally closed.
N373 Check Valve with One-touch Fitting AKH/AKB Series Bushing Type Can be used in applications with splashing coolant and spatter, etc.
T unit Can be connected with PLC I/O card for serial transmission.
They cannot be integrated into a unit. Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12
Tube coupler IN-442-5 Pressure probe Pressure can be supplied or stopped by inserting or removing the tube. Finger valve Pressure can be easily applied or released by switching the control. Used in combination with the pressure probe (IN442-5), total pressure can be easily measured. For specifications, refer to page 14-12-4. 14-12-2 3 Precautions Be sure to read before handling.
Tube coupler IN-442-5 Pressure probe Pressure can be supplied or stopped by inserting or removing the tube. Finger valve Pressure can be easily applied or released by switching the control. Used in combination with the pressure probe (IN442-5), total pressure can be easily measured. For specifications, refer to page 14-12-4. 14-12-2 3 Precautions Be sure to read before handling.
on the connections will be Nickel (no plated).
Since the products specified here are used in various operating conditions, their compatibility for the specific system must be based on specifications or after analysis and/or tests to meet your specific requirements. Be particularly careful in determining the compatibility of the fluid to be used. 2. Only trained personnel should operate machinery and equipment.
Assembly 1) Terminal box e connected with housing r should be reinstated.
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Electrical entry Symbol Specifications Configuration Body Ported Note) It cannot be mounted on a manifold.
If the valve is used with lubricated air, the factory pre-lubrication will be washed out so lubrication must be continued. 7. If lubricated air must be used, the external pilot type (VY1?01) and oilfree air supplied to the pilot port. 8. M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
B(9.5) B(12.7) B(19.1) 1B(25.4) 1 B(31.8) 1 B(38.1) 2B(50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 Caution Warning 1Piping When operation is suspended, surge pressure will be generated between the cylinder and VNA11A.
Standard Auto Switches Standard auto switches cannot be used under a strong magnetic field.