SMC Corporation of America
Elite Part Number Search
Search Results "ZH05DSA-06-01-06"

plate assembly VK300-42-1A VQZ 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Option Valve stations 01 Nil 1 station None VZ Bracket VK300-43-1A With bracket (Not mounted) F 20 20 stations VS 2(A) port: Rc 1/8 Port size 01 Rc 1/8 VFN Type 42: Base mounted (A port side ported) How to Order Applicable solenoid valve VKF334Applicable blanking plate assembly VK300-42-1A VV3KF3 05 01 42 Solenoid direction

VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 Rated voltage 100VAC 200VAC 240VAC 6VDC 12VDC 24VDC 48VDC Rating symbol A1 A2 A3 LW06 LW2 LD4 LD8 DIN terminal Circuit diagram for connector with light The bushing may be damaged if the tightening torque of 0.8Nm is exceeded.

Cylmoer IS unlocked allln"le of shipment See page 9 lor notes and Instruc~ons 01 engagHlg lOCk unit.

KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8

Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Circuit Diagram with Light AC circuit DC circuit Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure

Prefix it to the part nos. of the solenoid valve, etc. 3-3-74 5 Port Solenoid Valve Base Mounted Series VZ5000 Common SUP/Common EXH How to Order Type 40 VV5Z5 05 40 2 01 1(P) port Rc 1/4 4(A), 2(B) Port size Stations P, R port thread type 02 2 stations 01 Rc1 8 Rc Nil 3/5(R) port G F 20 20 stations Rc 1/4 N NPTF T NPT 4(A), 2(B) port Note) For more than 10 stations, supply air to both

Example) AW30K-03BE-1N-B B AW 30 03 BE K q w e r t y q Body size 20 30 40 60 Symbol Description w With backflow function Nil Without backflow function K Note 1) With backflow function + e Pipe thread type Nil Rc N Note 2) NPT F Note 3) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 r Port size 10 1 + a Mounting Nil Without mounting option B Note 5) With bracket H With set nut (for panel mount

In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. 1 1 2 4 5 3 5 3 10 Series VQ7-6 Optional Manifold Parts Silencer box Pilot EXH silencer VV71---SB AN110-01 This can be provided as a unit on

Port size Symbol Port size Rated flow range 03 06 12 10 1 14 1 1/2 20 2 Output specification Symbol OUT FUNC*2 Applicable monitor unit model CS NPN Analog voltage output*3 External input*4 PFG300 series DS NPN Analog current output External input*4 PFG310 series ES PNP Analog voltage output*3 External input*4 PFG300 series FS PNP Analog current output External input*4 PFG310 series *2

Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 5 32" Control type 04 06 08 10 12 03 05 07 09 11 13 3 16" Meter-out Meter-in 0 1 AS-FG 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.

How to Order Made to Order 2 F 06 A 200 AS Lubricant: Vaseline -X12 Example) AS2002F-04A-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Push-lock type Example) AS2002F-04A-X21 Not particle-free Applicable tubing O.D.1 Metric size Inch size 23 3.22 01

Metric size Inch size Body size Port size 06 6 3 1/8 standard 07 1/4 Symbol Cylinder side 08 8 4 1/4 standard 09 5/16 01 R1/8 10 10 11 3/8 5 3/8 standard 02 R1/4 12 12 13 1/2 6 1/2 standard 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series XTO257102 Applicable tubing O.D.

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08 8

Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)

02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 Applicable tubing O.D. mm 3.2 4 6 8 10 12 16 Applicable hose I.D.

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6)

Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6)

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6), Accessories: NS (w/o Standard Bracket, w/Silencer)

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6), Accessories: N (w/o Bracket, w/o Silencer)

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6)