Air temperature (C) 20 10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 40 Series VQ7-6/7-8 Specific Product Precautions 1 Be sure to read before handling. Refer to pages 37 through 40 for safety instructions and common precautions.
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
320.05 0.50.05 8 D B Piping port 2-M50.8 47 13 J Mounting base side B D 16.5 14.5 Across AA MXP16-30 Without magnet and switch rail 2-M20.4, 3 deep For magnet mounting 2-M30.5, 3.5 deep 8 For rail mounting 10.7 8.5 6-M50.8 20 20 7 deep L (mm) Model G H J K L M S V W Z MXP16-20 18 58 93 40 36 40 20 82 65 102 MXP16-30 28 70 119 50 42 56 30 108 75 128 170 170 Precision Air Slide Table Series
Grade 3 0.6 101 Grade 2 0.4 100 Grade 1 10-1 0.2 0 0.1 0.2 0.3 0.5 1 -20 0 20 40 60 80 Particle diameter m or less Operating temperature C 1 Clean One-touch Fittings Series KP How to Order KP H 06 KP P 08 01 Applicable fitting size Port size/Applicable tubing O.D.
For sonic range Where P1 = 0.10132 (P2 + 0.1013) Formula based on Cv factor Q = 98.9Cv (P1 + 0.1013) kg/h Formula based on effective area Q = 5.5S (P1 + 0.1013) kg/h 1 5 20 3 4 20 1 0 30 40 30 20 40 20 30 30 40 20 50 60 60 50 40 30 20 3 4 30 40 50 Figures inside [ ] indicate the saturated steam holding heat (kcal/kg). Figures inside ( ) indicate the saturation temperature (C).
For MGQM50-40 st, MGQM50-50 st is provided with a 10 mm width spacer.
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/
Change of fluid passage Flow Characteristics Flow characteristics 1 2 (P A) C [dm 3/(sbar)] 27 38 Port size 2 3 (A R) C [dm 3/(sbar)] 27 40 2 1 (A P) C [dm 3/(sbar)] 25 40 3 2 (R A) C [dm 3/(sbar)] 26 38 b 0.38 0.30 b 0.37 0.32 b 0.36 0.22 b 0.37 0.20 Cv 7.0 9.8 Cv 7.4 9.8 Cv 7.3 9.8 Cv 6.8 9.6 1/2 3/4 N.C. N.O.
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 40 50 63 80 100 125 140 160 180 200 Average speed Series (mm/s) 1000 Perpendicular, upward actuation 900 800 700 600 500 400 300 200 100 Horizontal actuation VQ7-6-FG-S-A02 0 1000 900 800 700 600 500 400 300 200 100 0 Courtesy of Steven Engineering, Inc.-230
Air Cylinder Short Type Standard: Double Acting, Single Rod Series CM3 20, 25, 32, 40 RoHS How to Order CM3 L 40 150 M9BW With auto switch CDM3 L 150 40 With auto switch (Built-in magnet) Number of auto switches Rod end thread Nil S n Mounting 2 pcs. 1 pc. n pcs.
0.10 4.1 Metal seal 40 or less Pressure center VP4 0.48 VQ7-6-FIG-D-R 1.3 0.08 5.9 1.2 0.15 5.6 Rubber seal 45 or less Note 1) Based on JIS B 8375-1981 (Value for supply pressure of 0.5 MPa, with light/surge voltage suppressor, when using clean air.)
(The conductance is shown as a guide only.) 32 Initial pumping conductance 30 28 L/s () P=0.1MPa XLD-100 XLD-160 XLDV-100 XLDV-160 26 Initial pumping valve conductance l/s (Viscous flow) Shows flow rate 24 22 20 XLDV-63 XLDV-80 XLD-63 XLD-80 18 16 14 XLD-50 XLDV-50 12 10 XLDV-40 XLD-40 8 when P=0.1MPa 6 4 XLD-25 XLDV-25 2 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
LAT3LAT3MLAT3F600 350 700 Min. travel time [ms] Min. travel time [ms] Min. travel time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
Grade 3 0.6 101 Grade 2 0.4 100 Grade 1 10-1 0.2 0 0.1 0.2 0.3 0.5 1 -20 0 20 40 60 80 Particle diameter m or less Operating temperature C 1 Clean One-touch Fittings Series KP How to Order KP H 06 KP P 08 01 Applicable fitting size Port size/Applicable tubing O.D.
For sonic range Where P1 = 0.10132 (P2 + 0.1013) Formula based on Cv factor Q = 98.9Cv (P1 + 0.1013) kg/h Formula based on effective area Q = 5.5S (P1 + 0.1013) kg/h 1 5 20 3 4 20 1 0 30 40 30 20 40 20 30 30 40 20 50 60 60 50 40 30 20 3 4 30 40 50 Figures inside [ ] indicate the saturated steam holding heat (kcal/kg). Figures inside ( ) indicate the saturation temperature (C).
100 V Pulse input type (Incremental encoder) 200 V A 10 m Pulse input type (Absolute encoder) 100 V Pulse input type (Absolute encoder) 200 V Specifications 100 200 300 400 Standard stroke (mm) Body weight (kg) Operating temperature range (C) Work load (kg) Maximum speed (mm/s) Positioning repeatability (mm) Motor Encoder Lead screw Guide Motor/Screw connection Model 5.3 6.1 6.9 7.7 5 to 40
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 02 (Rc1/4), Thread: T (NPTF)