(mm) Connection thread Rc T (M) Width across flat M Weight (g) Mounting hole L1 L2 Model H1 H2 KQB2E23-02 KQB2E04-01 KQB2E04-02 KQB2E06-01 KQB2E06-02 KQB2E06-03 KQB2E08-01 KQB2E08-02 KQB2E08-03 KQB2E10-02 KQB2E10-03 KQB2E12-03 KQB2E12-04 KQB2E16-03 KQB2E16-04 3.2 3.4 1/4 1/8 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/4 3/8 3/8 1/2 3/8 1/2 17 14 17 11 12 31 25.8 30.9 24.2 31.6 33 26.3 32.4 34 31.6 33.6
Description Hydraulic fluid type O-ring for cover case O-ring for element Spring Model FH150Standard Standard 02 03 04 02 03 04 Petroleum, Emulsion, Water-glycol JIS B2401 -1A-P30 1A-S65 JIS B2401 -4D-P30 Phosphoric ester FH1504D-S65 26 Oil Filter Series FH150 Flow Characteristics Differential Pressure Indication Handling Precautions FH150-02 to 04 Two indication methods are available: differential
Symbol Stations Note 02 2 stations P, E port entry Double wiring Note 1) U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) 16 02 16 stations 2 stations Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet.
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
Setting of switch operation 1_P/1_n (page 41) (Selection of display colour) Setting of Add dEC1 dEC2 (page 45) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 44) (page 41) (page 43) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 42) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 45) 6.
Base mounted VK300-41-2A Manifold gasket and screw assembly Note 1) Mounting direction is fixed, do not mount on opposite side.
Body size 10 20 30 40 50 60 AV Thread type AU Metric thread (M5) Rc NPT G Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order. Note 2) For M5 and NPT thread types.
(SeeLECSS Operation Manual (Simplified Edition),section 6.3.2 for uploading.) -41- 6.8.2 To Load saved Parameters From the Project menu in the setup software, select Open. Please select the "drive path name project name" that you want to read parameters from. Click Open.
34 M42 x 1.5 34 1 Optional specifications Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) ARP30(K) ARP40(K) H J H J H J M N Q R S T U V W Y l28 l27.8 37.5 29.5 40 66 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 l28 l27.8 37.5 30.5 41 67 41 40 44 6.5 8 53 2.3 31 38.5 19 7 l28 l27.8 42.5 35 45 74 50
x 4 nylon tubing Name plate and caution plate for bowl in imperial units (PSI, F) Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size 10 20 30 40 50 60 Thread type Metric thread (M5) Rc NPT G Nil N F AL20 Port size Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01 02
The standard angle adjustment range of 5 (one side) is changed to in this type. + 5 95 (mm) E Mounting screw Q Stroke 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 Size Y 58.5 ( 5 Stroke)/2 61 ( 10 Stroke)/2 61 ( 15 Stroke)
18 41 00 Belgium (32) 3-355 14 64 Netherlands (31) 20-531 8 Germany (49) 6103 4020 Sweden (46) 8-603 12 00 (420) 5-414 24611 Norway (47) 67 12 90 20 Austria (43) 2262-62 280 Italy (39) 02-927 11 Country Telephone Country Telephone SMC Corporation www.smcworld.com Kingdom Ireland (351) 1-403 9000 United SMC Europe www.smceu.com 12.European Contact List *SMC Corporation *Websites Republic Czech
) 1.2 (30) 1.2 (30) 1.6 (41) 1.9 (49) 1.0 (25) 5.8 (148) 5.4 (138) 5.4 (138) 0.35 (9) (8.0 (204)) 0.59 (15) 7.8 (198) DC connector Facility water outlet Rc1/4 Facility water inlet Rc1/4 For -N spec.
34 M42 x 1.5 34 1 Optional specifications Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) ARP30(K) ARP40(K) H J H J H J M N Q R S T U V W Y l28 l27.8 37.5 29.5 40 66 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 l28 l27.8 37.5 30.5 41 67 41 40 44 6.5 8 53 2.3 31 38.5 19 7 l28 l27.8 42.5 35 45 74 50
9 23 20 28 17 13 M10 x 1.5 M16 x 1.5 25 22 73 17 35 53 20 26 3/8 30 18 112 43 63 21 55 16 8 27 22.4 30 17 13 M10 x 1.5 M18 x 1.5 28 25 80 17 40 60 22 26 3/8 30 20 116 47 80 26 65 M12 x 1.75 18 8 31 28 32 22 15 M22 x 1.5 32 29 100 20 45 75 26 30 1/2 35 22 127 57 100 34 80 M27 x 2 M12 x 1.75 20 6.5 35 35.5 35 27 16 38 34 118 19 50 90 27 32 1/2 35 24 137 66 125 34 80 M14 x 2 M27 x 2 22 6.5 41
(-Q) (S) 42 (-Q) VV3K3-20 (-Q) 21 (-Q) VV5K3-20 (-Q) 21 (-Q) Manifold base Manifold base Caution Mounting Screw Tightening Torques M3: 0.6 Nm Body ported VK300-41-1A Base mounted VK300-41-2A Manifold gasket and screw assembly Note1) Mounting direction is fixed, do not mount on opposite side.
The standard angle adjustment range of 5 (one side) is changed to in this type. + 5 95 (mm) E Mounting screw Y Q Stroke 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 Size 58.5 ( 5 Stroke)/2 61 ( 10 Stroke)/2 61 ( 15 Stroke)
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
Free flow Controlled flow Weight (g) Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) Critical pressure ratio Critical pressure ratio Model Port size Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS1000-M3 AS1000-M5 AS2000-01 AS2000-02 AS3000-02 AS3000-03 AS4000-02 AS4000-03 AS4000-04 AS5000-02 AS5000-03 AS5000-04 0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7
(This product will continue operation.) (12) [ ] lamp Lights up when AL.01 Tank level drop failure or AL.02 Tank level dropalarm is generated.