Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.
Digital flow switch Air combination Spacer Spacer with bracket Pipe adapter PF3A701H AC30#-D Y300-D Y300T-D E300-#03-D PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). -17No.PF-OMX0007-A
cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M Model IDUS3E IDUS4E Port size J A B C D E F G H K L M 260 470 540 85 130 297 330 315 380 325 440 350 Rc 1/2 85 130 Rc 1/2 260 560 540 440 325 530 297 330 315 470 IDUS6E 315 130 605 540 Rc 3/4 515 485 325 355 325 575 285 110 Note: The diagram above is drawn base on IDUS3E dimension with scale 1:6 3 Stainless Steel Heat Exchanger
(Operating pressure: 0.5 MPa, unloaded, Piping: Bore 19 mm x 1 m) Although the converter and the valve unit are integrated, they can also be operated by providing individual piping. 100 CC S 63 1 1 1 G Converter nominal size Electrical entry of solenoid valve 63 100 160 63 mm 100 mm 160 mm Nil G C D Air operated Grommet Conduit DIN terminal Effective oil level stroke (mm) Valve unit size
(Operating pressure: 0.5 MPa, unloaded, Piping: Bore 19 mm x 1 m) Although the converter and the valve unit are integrated, they can also be operated by providing individual piping. 100 CC S 63 1 1 1 G Converter nominal size Electrical entry of solenoid valve 63 100 160 63 mm 100 mm 160 mm Nil G C D Air operated Grommet Conduit DIN terminal Courtesy of Steven Engineering, Inc.-230 Ryan Way
Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.
Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.
Other shapes do not comply with ISO1603 or ISO1179. 8) Light/surge voltage suppressor 7) Electrical entry Z Light/surge voltage suppressor L Lead wire length 0.3(m) L shaped plug connector LO Without connectors M Lead wire length 0.3(m) M plug connector MO Without connectors 9) Manual override Nil Non-locking push type D Push-turn locking slotted type E Push-turn locking (manual type) 10)
VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177
005 PCW 04 005 V Lead wire length Lead wire length Symbol 005 010 015 020 030 050 Lead wire length 0.5 m 1 m 1.5 m 2 m 3 m 5 m Symbol 005 010 015 020 030 050 Lead wire length 0.5 m 1 m 1.5 m 2 m 3 m 5 m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
D-C80 D-C73C, D-C80C Reed BMA2-020 BMA2-032 BMA2-040 BMA2-025 D-H7A1, D-H7A2, D-H7B, D-H7C D-H7NW, D-H7PW, D-H7BW D-H7LF, D-H7NF, D-H7BAL Solid state Reed Solid state D-B53, D-B54, D-B64, D-B59W D-G5NTL BA-32 BA-04 BA-01 BA-02 Reed Solid state D-A33, D-A34, D-A4 D-G39, D-K39 BD1-02M BD1-02 BD1-04M Precautions Be sure to read before handling.
cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M Model IDUS3E IDUS4E Port size J A B C D E H K L M F G 260 470 540 85 130 297 330 315 380 325 440 350 Rc 1/2 85 130 Rc 1/2 260 560 540 440 297 330 315 470 325 530 IDUS6E 315 130 605 540 Rc 3/4 515 485 325 355 325 575 285 110 Note: The diagram above is drawn base on IDUS3E dimension with scale 1:6 3 Stainless Steel Heat Exchanger
Series IDFS IDFS6E/8E/11E Evaporation thermometer G H Illumination switch Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J K Draft air outlet A B D E Power cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M A B Model IDFS6E IDFS8E Port size J C D M F
ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve None (Blanking plate) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Differential pressure indicator Differential pressure indication switch Note) Port size M E D 04 06 08 10 12 16 20 24 28 32 1/2B None
A lead wire with connector (2 m) is included.
ZB-OM00201-B Model Indication of the Replacement Parts (7) Supply valve, (8) Release valve Rated voltage 5 24 VDC 6 12 VDC Electrical entry Note 1) L L plug connector with lead wire LO L plug connector without lead wire M M plug connector with lead wire Note 2) MO M plug connector without lead wire Note 2) Note 1) All with light and surge suppressor.